KalAajKal.com :: Home Page  
Articles Quotations Lyrics Recipes Info               
Bookmark this Site  Set it as your HomePage                       
 
 
 Article Categories

  Animals articles  Animals
  Automobiles articles  Automobiles
  Business articles  Business
  Career articles  Career
  Computers articles  Computers
  Computer Programming articles  Computer Programming
  Entertainment articles  Entertainment
  Environment articles  Environment
  Family articles  Family
  Food articles  Food
  Health & Medical articles  Health & Medical
  Home & Garden articles  Home & Garden
  Humor articles  Humor
  Internet Marketing articles  Internet Marketing
  Legal articles  Legal
  Leisure & Recreation articles  Leisure & Recreation
  Marketing articles  Marketing
  Other articles  Other
  Politics articles  Politics
  Religion articles  Religion
  Sports articles  Sports
  Technology & Science articles  Technology & Science
  Travel articles  Travel
  Writing articles  Writing
  Finance articles  Finance
  Internet Business articles  Internet Business
  Communications articles  Communications
  Advice articles  Advice
  Self Improvement articles  Self Improvement
  Fashion articles  Fashion
  Reference & Education articles  Reference & Education
 
 
   


   
   
Categories :: Home & Garden Articles
  Hobbies   Home Accessories   Home Improvement   Home Repair   Home Security
  Interior Decorating   Landscaping
 


 

Category :: Home & Garden Author :: New Jersey Home Inspector Michael Del Greco 
 
 Article Title :: Carbon Monoxide in the Home
 
Carbon Monoxide in the Home

Submitted by: Michael Del Greco, New Jersey Home Inspector Lic GI 0121, President of Accurate Inspections, Inc, a New Jersey home inspection company

This silent killer claims about 1,500 lives each year in the U.S.

Carbon monoxide (CO) is one of the toxins that remains from incomplete combustion of fossil fuels. Fossil fuels include oil, gas, and coal. Small amounts of CO, such as those emitted from the kitchen range, will usually be found in the air in the home. These amounts pose no health concerns for the occupants.


However, health problems can develop if one is exposed to CO in large amounts, such as those emitted for many hours from a blocked chimney. In extreme cases, the presence of CO can be lethal.


BLOCKED CHIMNEYS, NOT HEAT EXCHANGERS, ARE THE REAL CULPRIT


Much has been written about heating systems causing dangerous levels of CO gas in homes. The heating furnace itself will not cause CO amounts of any concern to be emitted into the home.


If the heat exchanger fails (the heat exchanger is the part of the furnace that keeps burned fuels separate from the air in the living space) CO is rarely emitted in the air. If CO is emitted, the amount released is not significant. Here\'s why:


The typical furnace has a fan that circulates the indoor house air to and from the heating system and living space. This fan creates approximately 18 times more pressure on the house side air than the typical pressure created by atmospheric burners. In the event of a failure, this pressure causes the air from the living space to pass to the exhaust side of the unit and up the chimney.


This is not to say that a failed heat exchanger is acceptable. It is not. However, the likelihood of significant CO gas being delivered to the living space has been grossly overstated. A chimney that is blocked for many hours or days is the only item that would deliver dangerous amounts of CO gas to a dwelling.


THE REASONS WHY CO LEVELS VARY IN DIFFERENT HOMES


Carbon monoxide in homes is difficult to research due to numerous variables, including:

1) The size and air volume of a home. The more air in the home, the easier gases will dissipate.

2) The number of air changes per hour in modern homes that have thick insulation, etc.

3) The type of construction. Various types of frame and masonry construction will have an effect on the air changes and air infiltration.

4) The type of heating system. Combustion air requirements and efficiencies have some effect on air movement and changes.

5) Operating fans and exhaust systems. When on, these systems dissipate all the air in the house in minutes. The size of the systems and of the house will determine how effectively this is done.


According to an American National Standard\'s study on heat exchangers, leakage of waste gases is acceptable as long as the combustion chamber and vent do not leak more than 2% of flue gases. (Testing parameters are .1\" water column static pressure on the interior of the heat exchanger.)


HOW CO KILLS


CO reduces the ability of the hemoglobin in the blood to carry oxygen to the brain and body. This is akin to not breathing. The blood recovers quickly if the exposure is not continuous. Typical symptoms include headaches, fatigue, insomnia, nausea, and heart palpitations. The most desirable condition would be a zero level of CO.



Information provided by Michael Del Greco, New Jersey Home Inspector Lic. GI 0121, American Society of Home Inspectors Member 102273, Pesident of Accurate Inspections, Inc. A West Paterson New Jersey Home Inspection firm.

 
More Home & Garden Articles 
 
 

Content that published and provided on this web site is for informational purposes only. We accept no responsibility for any loss, damages or inconvenience sustained by any person or authority resulting from information published on this web site. We encourage and request you to verify any critical information with the relevant authorities.

   