and

Multi-species cryoEM calibration and workflow verification standard

Cryogenic electron microscopy (cryoEM) is a rapidly growing structural biology modality that has been successful in revealing molecular details of biological systems. However, unlike established biophysical and analytical techniques with calibration standards, cryoEM has lacked comprehensive biological test samples. Here, a cryoEM calibration sample consisting of a mixture of compatible macromolecules is introduced that can not only be used for resolution optimization, but also provides multiple reference points for evaluating instrument performance, data quality and image-processing workflows in a single experiment. This combined test specimen provides researchers with a reference point for validating their cryoEM pipeline, benchmarking their methodologies and testing new algorithms.




and

Duality of spaces and the origin of integral reflection conditions

The reciprocal of a non-primitive unit cell is not a unit cell and the basis vectors do not correspond to cell lengths.




and

Animations, videos and 3D models for teaching space-group symmetry

Animations, videos and 3D models have been designed to visualize the effects of symmetry operators on selected cases of crystal structures, pointing out the relationship with the diagrams published in International Tables for Crystallography, Vol. A.




and

Sheet-on-sheet fixed target data collection devices for serial crystallography at synchrotron and XFEL sources

Fixed targets (`chips') offer efficient, high-throughput microcrystal delivery for serial crystallography at synchrotrons and X-ray free-electron lasers (XFELs). Within this family, sheet-on-sheet (SOS) chips offer noteworthy advantages in cost, adaptability, universality and ease of crystal loading. We describe our latest generation of SOS devices, which are now in active use at both synchrotrons and XFELs.




and

Improving the reliability of small- and wide-angle X-ray scattering measurements of anisotropic precipitates in metallic alloys using sample rotation

Rotations of small- and wide-angle X-ray scattering samples during acquisition are shown to give a drastic improvement in the reliability of the characterization of anisotropic precipitates in metallic alloys.




and

Understanding secondary order parameters in perovskites with tilted octahedra

A symmetry guide for the secondary structural degrees of freedom and related physical properties generated by tilts of BX6 octahedra in perovskites is proposed.




and

Multi-scale and time-resolved structure analysis of relaxor ferroelectric crystals under an electric field

The electric field responses of the average and local lattice strains and polar nanoregions of relaxor ferroelectric PMN-30PT single crystals were revealed by multi-scale and time-resolved X-ray diffraction under DC and AC electric fields.




and

The effects of low boron incorporation on the structural and optical properties of BxGa1−xN/SiC epitaxial layers

The effect of boron in BxGa1−xN/SiC heteroepitaxy was established by X-ray diffraction reciprocal-space maps on symmetric 0002 and asymmetric 11 {overline 2} 4 reflections. The density of screw and edge threading dislocations was quantified in the framework of the mosaic model.




and

Small-angle scattering and dark-field imaging for validation of a new neutron far-field interferometer

A neutron far-field interferometer is under development at NIST with the aim of enabling a multi-scale measurement combining the best of small-angle neutron scattering (SANS) and neutron imaging and tomography. We use the close relationship between SANS, ultra-SANS, spin-echo SANS and dark-field imaging and measurements of monodisperse spheres as a validation metric, highlighting the strengths and weaknesses of each of these neutron techniques.




and

Characterization and calibration of DECTRIS PILATUS3 X CdTe 2M high-Z hybrid pixel detector for high-precision powder diffraction measurements

The performance of a high-Z photon-counting detector for powder diffraction measurements at high (>50 keV) energies is characterized, and the appropriate corrections are described in order to obtain data of higher quality than have previously been obtained from 2D detectors in these energy ranges.




and

Non-invasive nanoscale imaging of protein micro- and nanocrystals for screening crystallization conditions

The article presents a non-invasive nanoscale imaging technique that can be used in screening crystallization conditions for protein micro- and nanocrystals.




and

Optimal operation guidelines for direct recovery of high-purity precursor from spent lithium-ion batteries: hybrid operation model of population balance equation and data-driven classifier

This study proposes an operation optimization framework for impurity-free recycling of spent lithium-ion batteries. Using a hybrid population balance equation integrated with a data-driven condition classifier, the study firstly identifies the optimal batch and semi-batch operation conditions that significantly reduce the operation time with 100% purity of product; detailed guidelines are given for industrial applications.




and

TOMOMAN: a software package for large-scale cryo-electron tomography data preprocessing, community data sharing and collaborative computing

Here we describe TOMOMAN (TOMOgram MANager), an extensible open-sourced software package for handling cryo-electron tomography data preprocessing. TOMOMAN streamlines interoperability between a wide range of external packages and provides tools for project sharing and archival.




and

Specific radiation damage to halogenated inhibitors and ligands in protein–ligand crystal structures

This article reports an investigation into the effects of specific radiation damage to halogenated ligands in crystal structures of protein-inhibitor complexes.




and

Effect of thickness and noise on angular correlation analysis from scanning electron nanobeam diffraction of disordered carbon

The impact of sample thickness and experimental noise on angular correlation analysis from scanning electron nanobeam diffraction patterns of disordered carbon are investigated and analyzed regarding the interpretability of the analysis results.




and

Variable temperature studies of tetra­pyridine­silver(I) hexa­fluoro­phosphate and tetra­pyridine­silver(I) hexa­fluoro­anti­monate

Structures of tetra­pyridine­silver(I) hexa­fluoro­phosphate and tetra­pyridine silver(I) hexa­fluoro­anti­monate are reported from data collected at 300 K and 100 K.




and

The cadmium oxidotellurates(IV) Cd5(TeO3)4(NO3)2 and Cd4Te5O14

The crystal structure of Cd5(TeO3)4(NO3)2 exhibits a distinct layered arrangement, whereas Cd4Te5O14 crystallizes with a framework structure.




and

Crystal structure and Hirshfeld surface analysis of bis­(benzoyl­acetonato)(ethanol)dioxidouranium(VI)

In the complex, the ligand binds to the metal through an oxygen atom. The geometry of the seven-coordinate U atom is penta­gonal bipyramidal, with the uranyl O atoms in apical positions.




and

Synthesis and structure of penta­kis­(2-aminopyridinium) nona­vanado(V)tellurate(VI)

In the title compound, the tellurium(VI) and vanadium(V) atoms are statistically disordered over two of the ten metal-atom sites in the unprotonated [TeV9O28]5– heteropolyanion.




and

Crystal structures and circular dichroism of {2,2'-[(1S,2S)-1,2-di­phenyl­ethane-1,2-diylbis(nitrilophenyl­methanylyl­idene)]diphenolato}nickel(II) and its ethanol solvate

A chiral nickel(II) Schiff base complex derived from 2-hy­droxy­benzo­phenone and (1S,2S)-1,2-di­phenyl­ethyl­enedi­amine shows a λ conformation of the central di­amine chelate ring. The substituents on the C&z-dbnd;N carbon atoms significantly affect the circular dichroism spectra.




and

Crystal structure and Hirshfeld-surface analysis of an etoxazole metabolite designated R13

The crystal structure of a metabolite of the insecticide/acaricide etoxazole, designated R13 is presented along with a Hirshfeld surface analysis of inter­molecular inter­actions present in the crystal structure.




and

Crystal structure, Hirshfeld surface analysis, DFT and mol­ecular docking studies of ethyl 5-amino-2-bromo­isonicotinate

Theoretical and experimental structural studies of the title compound were undertaken using X-ray and DFT methods. The inter­actions present in the crystal were analyzed using Hirshfeld surface and MEP surface analysis. Docking studies with a covid-19 main protease (PDB ID: 6LU7) as the target receptor indicate that the synthesized compound may be a potential candidate for pharmaceutical applications.




and

Crystal structure, Hirshfeld surface, DFT and mol­ecular docking studies of 2-{4-[(E)-(4-acetylphen­yl)diazen­yl]phen­yl}-1-(5-bromo­thio­phen-2-yl)ethanone; a bromine⋯oxygen type contact

The title compound is a non-liquid crystal mol­ecule. The mol­ecular crystal is consolidated by C—Br⋯O&z-dbnd;C type contacts running continuously along the [001] direction.




and

Synthesis, crystal structure and Hirshfeld surface analysis of N-(4-meth­oxy­phen­yl)picolinamide

The mol­ecular and crystal structure of N-(4-meth­oxy­phen­yl)picolinamide were studied and Hirshfeld surfaces and fingerprint plots were generated to investigate various inter­molecular inter­actions.




and

Animations, videos and 3D models for teaching space-group symmetry

A series of animations, videos and 3D models that were developed, filmed or built to teach the symmetry properties of crystals are described. At first, these resources were designed for graduate students taking a basic crystallography course, coming from different careers, at the National Autonomous University of Mexico. However, the COVID-19 pandemic had the effect of accelerating the generation of didactic material. Besides our experience with postgraduate students, we have noted that 3D models attract the attention of children, and therefore we believe that these models are particularly useful for teaching children about the assembled arrangements of crystal structures.




and

Small-angle scattering and dark-field imaging for validation of a new neutron far-field interferometer

The continued advancement of complex materials often requires a deeper understanding of the structure–function relationship across many length scales, which quickly becomes an arduous task when multiple measurements are required to characterize hierarchical and inherently heterogeneous materials. Therefore, there are benefits in the simultaneous characterization of multiple length scales. At the National Institute of Standards and Technology, a new neutron far-field interferometer is under development that aims to enable a multi-scale measurement combining the best of small-angle neutron scattering (SANS) and neutron imaging and tomography. Spatially resolved structural information on the same length scales as SANS (0.001–1 µm) and ultra-small-angle neutron scattering (USANS, 0.1–10 µm) will be collected via dark-field imaging simultaneously with regular attenuation radiography (>10 µm). The dark field is analogous to the polarization loss measured in spin-echo SANS (SESANS) and is related to isotropic SANS through a Hankel transform. Therefore, we use this close relationship and analyze results from SANS, USANS, SESANS and dark-field imaging of monodisperse spheres as a validation metric for the interferometry measurements. The results also highlight the strengths and weaknesses of these neutron techniques for both steady-state and pulsed neutron sources. Finally, we present an example of the value added by the spatial resolution enabled by dark-field imaging in the study of more complex heterogeneous materials. This information would otherwise be lost in other small-angle scattering measurements averaged over the sample.




and

The effects of low boron incorporation on the structural and optical properties of BxGa1−xN/SiC epitaxial layers

BGaN epilayers with boron contents up to 5.6% were grown on SiC substrates by metal–organic chemical vapor deposition. The effects of boron incorporation on the structural and optical properties were studied by high-resolution X-ray diffraction (XRD), atomic force microscopy (AFM), Raman spectroscopy and photoluminescence (PL) spectroscopy. XRD reciprocal-space maps around the symmetric 0002 and asymmetric 11 {overline 2} 4 reflections allowed evaluation of the lattice constants and lattice mismatch with respect to the underlying substrate. XRD rocking curves and AFM measurements indicated the mosaic microstructure of the epilayer. The impact of boron content on crystallite size, tilt and twist is evaluated and the correlation with threading dislocation density is discussed. The deterioration of optical properties with increasing boron content was assessed by Raman and PL spectroscopy.




and

Improving the reliability of small- and wide-angle X-ray scattering measurements of anisotropic precipitates in metallic alloys using sample rotation

Nanometric precipitates in metallic alloys often have highly anisotropic shapes. Given the large grain size and non-random texture typical of these alloys, performing small- and wide-angle X-ray scattering (SAXS/WAXS) measurements on such samples for determining their characteristics (typically size and volume fraction) results in highly anisotropic and irreproducible data. Rotations of flat samples during SAXS/WAXS acquisitions are presented here as a solution to these anisotropy issues. Two aluminium alloys containing anisotropic precipitates are used as examples to validate the approach with a −45°/45° angular range. Clear improvements can be seen on the SAXS I(q) fitting and the consistency between the different SAXS/WAXS measurements. This methodology results in more reliable measurements of the precipitate's characteristics, and thus allows for time- and space-resolved measurements with higher accuracy.




and

Understanding secondary order parameters in perovskites with tilted octahedra

In the family of perovskite materials, the tilts of BX6 octahedra are the most common type of structural distortion. Conventionally, the formation of low-symmetry perovskite phases with tilted octahedra is analyzed by considering only primary order parameters. However, octahedral tilting also gives rise to secondary order parameters which contribute to additional atomic displacements, ordering and lattice distortions. Our study highlights the significant impact of secondary order parameters on the structural formation and emergent physical properties of perovskites. Through group-theoretical and crystallographic analyses, we have identified all secondary order parameters within Glazer-type tilt systems and clarified their physical manifestations. We explore the fundamental symmetry relationships among various structural degrees of freedom in perovskites, including tilt-induced ferroelasticity, correlations between displacements and ordering of atoms occupying different positions, and the potential for rigid unit rotations and unconventional octahedral tilts. Particular emphasis is placed on the emergence of secondary order parameters and their coupling with primary order parameters, as well as their symmetry-based hierarchy, illustrated through a modified Bärnighausen tree. We applied our theoretical insights to elucidate phase transitions in well known perovskites such as CaTiO3 and RMnO3 (where R = La and lanthanide ions), thereby demonstrating the significant influence of secondary order parameters on crystal structure formation. Our results serve as a symmetry-based guide for the design, identification and structural characterization of perovskites with tilted octahedra, and for understanding tilt-induced physical properties.




and

Duality of spaces and the origin of integral reflection conditions

The dualism between direct and reciprocal space is at the origin of well known relations between basis vectors in the two spaces. It is shown that when a coordinate system corresponding to a non-primitive unit cell is adopted, this dualism has to be handled with care. In particular, the reciprocal of a non-primitive unit cell is not a unit cell but a region in reciprocal space that does not represent a unit of repetition by translation. The basis vectors do not correspond to reciprocal-space cell lengths, contrary to what is stated even in the core CIF dictionary. The corresponding unit cell is a multiple of this region. The broken correspondence between basis vectors and unit cell is at the origin of the integral reflection conditions.




and

Sheet-on-sheet fixed target data collection devices for serial crystallography at synchrotron and XFEL sources

Serial crystallography (SX) efficiently distributes over many crystals the radiation dose absorbed during diffraction data acquisition, enabling structure determination of samples at ambient temperature. SX relies on the rapid and reliable replacement of X-ray-exposed crystals with fresh crystals at a rate commensurate with the data acquisition rate. `Solid supports', also known as `fixed targets' or `chips', offer one approach. These are microscopically thin solid panes into or onto which crystals are deposited to be individually interrogated by an X-ray beam. Solid supports are generally patterned using photolithography methods to produce a regular array of features that trap single crystals. A simpler and less expensive alternative is to merely sandwich the microcrystals between two unpatterned X-ray-transparent polymer sheets. Known as sheet-on-sheet (SOS) chips, these offer significantly more versatility. SOS chips place no constraint on the size or size distribution of the microcrystals or their growth conditions. Crystals ranging from true nanocrystals up to microcrystals can be investigated, as can crystals grown in media ranging from low viscosity (aqueous solution) up to high viscosity (such as lipidic cubic phase). Here, we describe our two SOS devices. The first is a compact and lightweight version designed specifically for synchrotron use. It incorporates a standard SPINE-type magnetic base for mounting on a conventional macromolecular crystallography goniometer. The second and larger chip is intended for both X-ray free-electron laser and synchrotron use and is fully compatible with the fast-scanning XY-raster stages developed for data collection with patterned chips.




and

Multi-scale and time-resolved structure analysis of relaxor ferroelectric crystals under an electric field

Lead-based relaxor ferroelectrics exhibit giant piezoelectric properties owing to their heterogeneous structures. The average and local structures measured by single-crystal X-ray diffraction under DC and AC electric fields are reviewed in this article. The position-dependent local lattice strain and the distribution of polar nanodomains and nanoregions show strong electric field dependence, which contributes to the giant piezoelectric properties.




and

Lattice symmetry relaxation as a cause for anisotropic line broadening and peak shift in powder diffraction

In powder diffraction, lattice symmetry relaxation causes a peak to split into several components which are not resolved if the degree of desymmetrization is small (pseudosymmetry). Here the equations which rule peak splitting are elaborated for the six minimal symmetry transitions, showing that the resulting split peaks are generally broader and asymmetric, and suffer an hkl-dependent displacement with respect to the high-symmetry parent peak. These results will be of help in Rietveld refinement of pseudosymmetric structures where an exact interpretation of peak deformation is required.




and

Influence of device configuration and noise on a machine learning predictor for the selection of nanoparticle small-angle X-ray scattering models

Small-angle X-ray scattering (SAXS) is a widely used method for nanoparticle characterization. A common approach to analysing nanoparticles in solution by SAXS involves fitting the curve using a parametric model that relates real-space parameters, such as nanoparticle size and electron density, to intensity values in reciprocal space. Selecting the optimal model is a crucial step in terms of analysis quality and can be time-consuming and complex. Several studies have proposed effective methods, based on machine learning, to automate the model selection step. Deploying these methods in software intended for both researchers and industry raises several issues. The diversity of SAXS instrumentation requires assessment of the robustness of these methods on data from various machine configurations, involving significant variations in the q-space ranges and highly variable signal-to-noise ratios (SNR) from one data set to another. In the case of laboratory instrumentation, data acquisition can be time-consuming and there is no universal criterion for defining an optimal acquisition time. This paper presents an approach that revisits the nanoparticle model selection method proposed by Monge et al. [Acta Cryst. (2024), A80, 202–212], evaluating and enhancing its robustness on data from device configurations not seen during training, by expanding the data set used for training. The influence of SNR on predictor robustness is then assessed, improved, and used to propose a stopping criterion for optimizing the trade-off between exposure time and data quality.




and

Symmetries and symmetry-generated averages of elastic constants up to the sixth order of nonlinearity for all crystal classes, isotropy and transverse isotropy

Algebraic expressions for averaging linear and nonlinear stiffness tensors from general anisotropy to different effective symmetries (11 Laue classes elastically representing all 32 crystal classes, and two non-crystalline symmetries: isotropic and cylindrical) have been derived by automatic symbolic computations of the arithmetic mean over the set of rotational transforms determining a given symmetry. This approach generalizes the Voigt average to nonlinear constants and desired approximate symmetries other than isotropic, which can be useful for a description of textured polycrystals and rocks preserving some symmetry aspects. Low-symmetry averages have been used to derive averages of higher symmetry to speed up computations. Relationships between the elastic constants of each symmetry have been deduced from their corresponding averages by resolving the rank-deficient system of linear equations. Isotropy has also been considered in terms of generalized Lamé constants. The results are published in the form of appendices in the supporting information for this article and have been deposited in the Mendeley database.




and

Crystal structure, Hirshfeld surface analysis, DFT and molecular docking studies of ethyl 5-amino-2-bromoisonicotinate

In the title compound, C8H9BrN2O2, the C—O—C—C torsion angle between isonicotine and the ethyl group is 180.0 (2)°. Intramolecular N—H...O and C—H...O interactions consolidate the molecular structure. In the crystal, N—H...N interaction form S(5) zigzag chains along [010]. The most significant contributions to the Hirshfeld surface arise from H...H (33.2%), Br...H/H...Br (20.9%), O...H/H...O (11.2%), C...H/H...C (11.1%) and N...H/H...N (10%) contacts. The topology of the three-dimensional energy frameworks was generated using the B3LYP/6–31 G(d,p) model to calculate the total interaction energy. The net interaction energies for the title compound are Eele = 59.2 kJ mol−1, Epol = 15.5 kJ mol−1, Edis = 140.3 kJ mol−1 and Erep = 107.2 kJ mol−1 with a total interaction energy Etot of 128.8 kJ mol−1. The molecular structure was optimized by density functional theory (DFT) at the B3LYP/6–311+G(d,p) level and the theoretical and experimentally obtained parameters were compared. The frontier molecular orbitals HOMO and LUMO were generated, giving an energy gap ΔE of 4.0931 eV. The MEP was generated to identify active sites in the molecule and molecular docking studies carried out with the title compound (ligand) and the covid-19 main protease PDB ID: 6LU7, revealing a moderate binding affinity of −5.4 kcal mol−1.




and

Crystal structure and Hirshfeld-surface analysis of an etoxazole metabolite designated R13

The etoxazole metabolite R13, systematic name 4-(4-tert-butyl-2-ethoxyphenyl)-2-(2,6-difluorophenyl)oxazole (C21H21F2NO2), results from the oxidation of etoxazole, a chitin synthesis inhibitor belonging to the oxazoline class, widely used as an insecticide/acaricide since 1998. The structure of R13 features a central oxazole ring with attached 2,6-difluorophenyl and 4-t-butyl-2-ethoxyphenyl moieties. The overall conformation gives dihedral angles between these rings and the oxazole of 24.91 (5)° (with difluorophenyl) and 15.30 (6)° (with t-butyl-ethoxyphenyl), indicating an overall deviation from planarity. Additionally, torsion angles of the ethoxy and t-butyl groups define the orientation of these substituents relative to their benzene ring. In the crystal packing, no significant hydrogen bonds are present, but a Hirshfeld surface analysis highlights weak intermolecular contacts leading to π–π-stacked dimers linked by weak C—H...N contacts. The packing analysis confirms that most intermolecular interactions involve hydrogen atoms.




and

Crystal structures and circular dichroism of {2,2'-[(1S,2S)-1,2-diphenylethane-1,2-diylbis(nitrilophenylmethanylylidene)]diphenolato}nickel(II) and its ethanol solvate

The title compound, [Ni(C40H30N2O2)] (1), with an optically active Schiff base ligand derived from 2-hydroxybenzophenone and (1S,2S)-1,2-diphenylethylenediamine, was crystallized as the solvent-free and ethanol solvate forms (1 and 1·2C2H5OH). In both structures, the two phenyl groups on the stereogenic centers of the O,N,N,O-tetradentate ligand are axially oriented, and the conformation of the central diamine chelate ring is λ. The circular dichroism (CD) spectra of 1 and the analogous nickel(II) complex [Ni(C30H26N2O2)] (2) in solution show partially similar patterns in the 350–450 nm range, but are mirror images in the longer wavelength region (450–650 nm). In the latter region, the sign of CD for these complexes is sensitive to the substituents on the C=N carbon atoms (phenyl for 1 and methyl for 2) rather than the diamine chelate ring conformation.




and

In situ/operando plug-flow fixed-bed cell for synchrotron PXRD and XAFS investigations at high temperature, pressure, controlled gas atmosphere and ultra-fast heating

A plug-flow fixed-bed cell for synchrotron powder X-ray diffraction (PXRD) and X-ray absorption fine structure (XAFS) idoneous for the study of heterogeneous catalysts at high temperature, pressure and under gas flow is designed, constructed and demonstrated. The operating conditions up to 1000°C and 50 bar are ensured by a set of mass flow controllers, pressure regulators and two infra-red lamps that constitute a robust and ultra-fast heating and cooling method. The performance of the system and cell for carbon dioxide hydrogenation reactions under specified temperatures, gas flows and pressures is demonstrated both for PXRD and XAFS at the P02.1 (PXRD) and the P64 (XAFS) beamlines of the Deutsches Elektronen-Synchrotron (DESY).




and

The African Light Source: history, context and future

The African Light Source (AfLS) project is now almost eight years old. This article assesses the history, current context and future of the project. There is by now considerable momentum in building the user community, including deep training, facilitating access to current facilities, growing the scientific output, scientific networks and growing the local laboratory-scale research infrastructure. The Conceptual Design Report for the AfLS is in its final editing stages. This document specifies the socio-economic and scientific rationales and the technical aspects amongst others. The AfLS is supported by many national and Pan-African scientific professional bodies and voluntary associates across many scientific disciplines, and there are stakeholders throughout the continent and beyond. The current roadmap phases have expanded to include national and Pan-African level conversations with policy makers through new Strategic Task Force groups. The document summarizes this progress and discusses the future of the project.




and

Performance of a photoelectron momentum microscope in direct- and momentum-space imaging with ultraviolet photon sources

The Photoelectron-Related Image and Nano-Spectroscopy (PRINS) endstation located at the Taiwan Photon Source beamline 27A2 houses a photoelectron momentum microscope capable of performing direct-space imaging, momentum-space imaging and photoemission spectroscopy with position sensitivity. Here, the performance of this microscope is demonstrated using two in-house photon sources – an Hg lamp and He(I) radiation – on a standard checkerboard-patterned specimen and an Au(111) single crystal, respectively. By analyzing the intensity profile of the edge of the Au patterns, the Rashba-splitting of the Au(111) Shockley surface state at 300 K, and the photoelectron intensity across the Fermi edge at 80 K, the spatial, momentum and energy resolution were estimated to be 50 nm, 0.0172 Å−1 and 26 meV, respectively. Additionally, it is shown that the band structures acquired in either constant energy contour mode or momentum-resolved photoemission spectroscopy mode were in close agreement.




and

Protocol using similarity score and improved shrink-wrap algorithm for better convergence of phase-retrieval calculation in X-ray diffraction imaging

In X-ray diffraction imaging (XDI), electron density maps of a targeted particle are reconstructed computationally from the diffraction pattern alone using phase-retrieval (PR) algorithms. However, the PR calculations sometimes fail to yield realistic electron density maps that approximate the structure of the particle. This occurs due to the absence of structure amplitudes at and near the zero-scattering angle and the presence of Poisson noise in weak diffraction patterns. Consequently, the PR calculation becomes a bottleneck for XDI structure analyses. Here, a protocol to efficiently yield realistic maps is proposed. The protocol is based on the empirical observation that realistic maps tend to yield low similarity scores, as suggested in our prior study [Sekiguchi et al. (2017), J. Synchrotron Rad. 24, 1024–1038]. Among independently and concurrently executed PR calculations, the protocol modifies all maps using the electron-density maps exhibiting low similarity scores. This approach, along with a new protocol for estimating particle shape, improved the probability of obtaining realistic maps for diffraction patterns from various aggregates of colloidal gold particles, as compared with PR calculations performed without the protocol. Consequently, the protocol has the potential to reduce computational costs in PR calculations and enable efficient XDI structure analysis of non-crystalline particles using synchrotron X-rays and X-ray free-electron laser pulses.




and

In situ characterization of stresses, deformation and fracture of thin films using transmission X-ray nanodiffraction microscopy

The use of hard X-ray transmission nano- and microdiffraction to perform in situ stress and strain measurements during deformation has recently been demonstrated and used to investigate many thin film systems. Here a newly commissioned sample environment based on a commercially available nanoindenter is presented, which is available at the NanoMAX beamline at the MAX IV synchrotron. Using X-ray nanoprobes of around 60–70 nm at 14–16 keV and a scanning step size of 100 nm, we map the strains, stresses, plastic deformation and fracture during nanoindentation of industrial coatings with thicknesses in the range of several micrometres, relatively strong texture and large grains. The successful measurements of such challenging samples illustrate broad applicability. The sample environment is openly accessible for NanoMAX beamline users through the MAX IV sample environment pool, and its capability can be further extended for specific purposes through additional available modules.




and

Combination of XEOL, TR-XEOL and HB-T interferometer at the TPS 23A X-ray nanoprobe for exploring quantum materials

In this study, a combination of X-ray excited optical luminescence (XEOL), time-resolved XEOL (TR-XEOL) and the Hanbury-Brown and Twiss (HB-T) interferometer at the Taiwan Photon Source (TPS) 23A X-ray nanoprobe beamline for exploring quantum materials is demonstrated. On the basis of the excellent spatial resolution rendered using a nano-focused beam, emission distributions of artificial micro-diamonds can be obtained by XEOL maps, and featured emission peaks of a selected local area can be obtained by XEOL spectra. The hybrid bunch mode of the TPS not only provides a sufficiently high peak power density for experiments at each beamline but also permits high-quality temporal domain (∼200 ns) measurements for investigating luminescence dynamics. From TR-XEOL measurements, the decay lifetime of micro-diamonds is determined to be approximately 16 ns. Furthermore, the XEOL spectra of artificial micro-diamonds can be investigated by the HB-T interferometer to identify properties of single-photon sources. The unprecedented strategy of combining XEOL, TR-XEOL and the HB-T interferometer at the X-ray nanoprobe beamline will open new avenues with significant characterization abilities for unraveling the emission mechanisms of single-photon sources for quantum materials.




and

Correlation of refractive index based and THz streaking arrival time tools for a hard X-ray free-electron laser

To fully exploit ultra-short X-ray pulse durations routinely available at X-ray free-electron lasers to follow out-of-equilibrium dynamics, inherent arrival time fluctuations of the X-ray pulse with an external perturbing laser pulse need to be measured. In this work, two methods of arrival time measurement were compared to measure the arrival time jitter of hard X-ray pulses. The methods were photoelectron streaking by a THz field and a transient refractive index change of a semiconductor. The methods were validated by shot-to-shot correction of a pump–probe transient reflectivity measurement. An ultimate shot-to-shot full width at half-maximum error between the devices of 19.2 ± 0.1 fs was measured.




and

Submillisecond in situ X-ray diffraction measurement system with changing temperature and pressure using diamond anvil cells at BL10XU/SPring-8

Recently, there has been a high demand for elucidating kinetics and visualizing reaction processes under extreme dynamic conditions, such as chemical reactions under meteorite impact conditions, structural changes under non­equilibrium conditions, and in situ observations of dynamic changes. To accelerate material science studies and Earth science fields under dynamic conditions, a submillisecond in situ X-ray diffraction measurement system has been developed using a diamond anvil cell to observe reaction processes under rapidly changing pressure and temperature conditions replicating extreme dynamic conditions. The development and measurements were performed at the high-pressure beamline BL10XU/SPring-8 by synchronizing a high-speed hybrid pixel array detector, laser heating and temperature measurement system, and gas-pressure control system that enables remote and rapid pressure changes using the diamond anvil cell. The synchronized system enabled momentary heating and rapid cooling experiments up to 5000 K via laser heating as well as the visualization of structural changes in high-pressure samples under extreme dynamic conditions during high-speed pressure changes.




and

xrdPlanner: exploring area detector geometries for powder diffraction and total scattering experiments

xrdPlanner is a software package designed to aid in the planning and preparation of powder X-ray diffraction and total scattering beam times at synchrotron facilities. Many modern beamlines provide a flexible experimental setup and may have several different detectors available. In combination with a range of available X-ray energies, it often makes it difficult for the user to explore the available parameter space relevant for a given experiment prior to the scheduled beam time. xrdPlanner was developed to provide a fast and straightforward tool that allows users to visualize the accessible part of reciprocal space of their experiment at a given combination of photon energy and detector geometry. To plan and communicate the necessary geometry not only saves time but also helps the beamline staff to prepare and accommodate for an experiment. The program is tailored toward powder X-ray diffraction and total scattering experiments but may also be useful for other experiments that rely on an area detector and for which detector placement and achievable momentum-transfer range are important experimental parameters.




and

Extracting the electronic structure signal from X-ray and electron scattering in the gas phase

X-ray and electron scattering from free gas-phase molecules is examined using the independent atom model (IAM) and ab initio electronic structure calculations. The IAM describes the effect of the molecular geometry on the scattering, but does not account for the redistribution of valence electrons due to, for instance, chemical bonding. By examining the total, i.e. energy-integrated, scattering from three molecules, fluoroform (CHF3), 1,3-cyclohexadiene (C6H8) and naphthalene (C10H8), the effect of electron redistribution is found to predominantly reside at small-to-medium values of the momentum transfer (q ≤ 8 Å−1) in the scattering signal, with a maximum percent difference contribution at 2 ≤ q ≤ 3 Å−1. A procedure to determine the molecular geometry from the large-q scattering is demonstrated, making it possible to more clearly identify the deviation of the scattering from the IAM approximation at small and intermediate q and to provide a measure of the effect of valence electronic structure on the scattering signal.




and

Open-source electrochemical cell for in situ X-ray absorption spectroscopy in transmission and fluorescence modes

X-ray spectroscopy is a valuable technique for the study of many materials systems. Characterizing reactions in situ and operando can reveal complex reaction kinetics, which is crucial to understanding active site composition and reaction mechanisms. In this project, the design, fabrication and testing of an open-source and easy-to-fabricate electrochemical cell for in situ electrochemistry compatible with X-ray absorption spectroscopy in both transmission and fluorescence modes are accomplished via windows with large opening angles on both the upstream and downstream sides of the cell. Using a hobbyist computer numerical control machine and free 3D CAD software, anyone can make a reliable electrochemical cell using this design. Onion-like carbon nanoparticles, with a 1:3 iron-to-cobalt ratio, were drop-coated onto carbon paper for testing in situ X-ray absorption spectroscopy. Cyclic voltammetry of the carbon paper showed the expected behavior, with no increased ohmic drop, even in sandwiched cells. Chronoamperometry was used to apply 0.4 V versus reversible hydrogen electrode, with and without 15 min of oxygen purging to ensure that the electrochemical cell does not provide any artefacts due to gas purging. The XANES and EXAFS spectra showed no differences with and without oxygen, as expected at 0.4 V, without any artefacts due to gas purging. The development of this open-source electrochemical cell design allows for improved collection of in situ X-ray absorption spectroscopy data and enables researchers to perform both transmission and fluorescence simultaneously. It additionally addresses key practical considerations including gas purging, reduced ionic resistance and leak prevention.




and

Ultrashort large-bandwidth X-ray free-electron laser generation with a dielectric-lined waveguide

Large-bandwidth pulses produced by cutting-edge X-ray free-electron lasers (FELs) are of great importance in research fields like material science and biology. In this paper, a new method to generate high-power ultrashort FEL pulses with tunable spectral bandwidth with spectral coherence using a dielectric-lined waveguide without interfering operation of linacs is proposed. By exploiting the passive and dephasingless wakefield at terahertz frequency excited by the beam, stable energy modulation can be achieved in the electron beam and large-bandwidth high-intensity soft X-ray radiation can be generated. Three-dimensional start-to-end simulations have been carried out and the results show that coherent radiation pulses with duration of a few femtoseconds and bandwidths ranging from 1.01% to 2.16% can be achieved by changing the undulator taper profile.