i Text variables By community.cadence.com Published On :: Tue, 14 Dec 2021 11:07:34 GMT Hello, I was wondering how can I create variable fields in the layout. To start, I have a template for some type of designs, and I would like that one of the texts on the silkscreen changes accordingly to an external variable, like the folder name, or a text file in the same folder. I was thinking something similar to a page frame that changes the date automatically. How can I generate that type of fields? Full Article
i 17.4 Design Sync Fails without providing errors By community.cadence.com Published On :: Tue, 14 Dec 2021 14:06:09 GMT As the title suggests I am unable to perform design sync between OrCAD Capture and Allegro. When I add a layout and try to sync to it I am given ERROR(ORCAP-2426): Cannot run Design Sync because of errors. See session log for error details. Session Log [ORPCBFLOW] : Invoking ECO dialog.INFO(ORNET-1176): Netlisting the designINFO(ORNET-1178): Design Name:C:USERSDDOYLEDOCUMENTSCADENCEBOARDSREMOTE POWER DEVICECAPTUREREMOTE_POWER_DEVICE.DSNNetlist Directory:c:usersddoyledocumentscadenceoards emote power devicelayoutallegroConfiguration File:C:CadenceSPB_17.4 ools/capture/allegro.cfgpstswp.exe - pst - d "C:USERSDDOYLEDOCUMENTSCADENCEBOARDSREMOTE POWER DEVICECAPTUREREMOTE_POWER_DEVICE.DSN"- n "c:usersddoyledocumentscadenceoards emote power devicelayoutallegro" - c "C:CadenceSPB_17.4 ools/capture/allegro.cfg" - v 3 - l 31 - s "" - j "PCB Footprint" - hpath "HPathForCollision"Spawning... pstswp.exe - pst - d "C:USERSDDOYLEDOCUMENTSCADENCEBOARDSREMOTE POWER DEVICECAPTUREREMOTE_POWER_DEVICE.DSN"- n "c:usersddoyledocumentscadenceoards emote power devicelayoutallegro" - c "C:CadenceSPB_17.4 ools/capture/allegro.cfg" - v 3 - l 31 - s "" - j "PCB Footprint" - hpath "HPathForCollision"{ Using PSTWRITER 17.4.0 d001Dec-14-2021 at 09:00:49 } INFO(ORCAP-36080): Scanning netlist files ... Loading... c:usersddoyledocumentscadenceoards emote power devicelayoutallegropstchip.dat Loading... c:usersddoyledocumentscadenceoards emote power devicelayoutallegropstchip.dat Loading... c:usersddoyledocumentscadenceoards emote power devicelayoutallegropstxprt.dat Loading... c:usersddoyledocumentscadenceoards emote power devicelayoutallegropstxnet.datpackaging the design view...Exiting... pstswp.exe - pst - d "C:USERSDDOYLEDOCUMENTSCADENCEBOARDSREMOTE POWER DEVICECAPTUREREMOTE_POWER_DEVICE.DSN"- n "c:usersddoyledocumentscadenceoards emote power devicelayoutallegro" - c "C:CadenceSPB_17.4 ools/capture/allegro.cfg" - v 3 - l 31 - s "" - j "PCB Footprint" - hpath "HPathForCollision"INFO(ORNET-1179): *** Done *** This issue started to occur after I changed parts that exist on previously created PCBs. I changed the following leading up to this: 1. Added height in Allegro to many of my components using the Setup->Area->Package Height tool. 2. Changed the reference designator category in OrCAD Capture to TP for several components on board. Any advice here would be most welcome. Thanks! Full Article
i CIS Standard BOM to Excel 365 By community.cadence.com Published On :: Tue, 14 Dec 2021 14:49:39 GMT I'm not able to export a CIS Standard BOM to a Microsoft 365 Excel (business subscription, version 2111).Selecting the "Export BOM report to Excel" option opens a new Excel window, but OrCAD (17.4-2019 S023) won't fill it with any data... I tried it on a different PC with Microsoft Office Professional Plus 2019 Excel (strangely the version number is the same: 2111) and with OrCAD 17.4-2019 S016 and it worked flawlessly. Does anybody experiencing the same issue?Does the Excel variant, the OrCAD version or the PC itself causing this?Thanks for any help! Full Article
i The default location of orCAD Capture library Pin Number is incorrect By community.cadence.com Published On :: Tue, 14 Dec 2021 21:38:21 GMT The default position of the pin number is incorrect. Full Article
i Allegro part of DPI does not support scaling above 150% By community.cadence.com Published On :: Tue, 14 Dec 2021 21:49:57 GMT Allegro part of DPI does not support scaling above 150% Full Article
i Migrating from files Orcad Layout 16.2 By community.cadence.com Published On :: Wed, 15 Dec 2021 02:55:48 GMT I have managed to convert our old schematic and PCD file to from Layout 16.2 to 17.4 I have exported the footprints and moved them to the correct lib directory. I get no DRC errors and I can build a new netlist file. The problem is I can't get the PCB editor to update using the new netlist and get the following error: I cannot figure out how to fix the Name is too long error. (---------------------------------------------------------------------) ( ) ( Allegro Netrev Import Logic ) ( ) ( Drawing : 70055R2.brd ) ( Software Version : 17.4S023 ) ( Date/Time : Tue Dec 14 18:54:25 2021 ) ( ) (---------------------------------------------------------------------) ------ Directives ------------ Ripup etch: Yes Ripup delete first segment: No Ripup retain bondwire: No Ripup symbols: IfSame Missing symbol has error: No DRC update: Yes Schematic directory: 'C:/AFS/70055 PCB Test 2' Design Directory: 'C:/AFS/70055 PCB Test 2' Old design name: 'C:/AFS/70055 PCB Test 2/70055R2.brd' New design name: 'C:/AFS/70055 PCB Test 2/70055R2.brd' CmdLine: netrev -$ -i C:/AFS/70055 PCB Test 2 -x -u -t -y 2 -h -z -q netrev_constraint_report.xml C:/AFS/70055 PCB Test 2/#Taaaaae57776.tmp ------ Preparing to read pst files ------ Starting to read C:/AFS/70055 PCB Test 2/pstchip.dat Finished reading C:/AFS/70055 PCB Test 2/pstchip.dat (00:00:00.02) Starting to read C:/AFS/70055 PCB Test 2/pstxprt.dat Finished reading C:/AFS/70055 PCB Test 2/pstxprt.dat (00:00:00.00) Starting to read C:/AFS/70055 PCB Test 2/pstxnet.dat Finished reading C:/AFS/70055 PCB Test 2/pstxnet.dat (00:00:00.00) ------ Oversights/Warnings/Errors ------ #1 ERROR(SPMHNI-176): Device library error detected. ERROR(SPMHNI-189): Problems with the name of device 'SW DPDT_9_SWITCH_OTTO_ALT_SW DPDT': 'Name is too long.'. ERROR(SPMHNI-170): Device 'SW DPDT_9_SWITCH_OTTO_ALT_SW DP' has library errors. Unable to transfer to Allegro. #2 ERROR(SPMHNI-176): Device library error detected. ERROR(SPMHNI-189): Problems with the name of device 'SW DPDT_10_SWITCH_OTTO_LIGHTS_SW DPDT': 'Name is too long.'. ERROR(SPMHNI-170): Device 'SW DPDT_10_SWITCH_OTTO_LIGHTS_S' has library errors. Unable to transfer to Allegro. #3 ERROR(SPMHNI-176): Device library error detected. ERROR(SPMHNI-189): Problems with the name of device 'SW DPDT_7_SWITCH_OTTO_ALT_SW DPDT': 'Name is too long.'. ERROR(SPMHNI-170): Device 'SW DPDT_7_SWITCH_OTTO_ALT_SW DP' has library errors. Unable to transfer to Allegro. #4 ERROR(SPMHNI-176): Device library error detected. ERROR(SPMHNI-189): Problems with the name of device 'SW DPDT_3_SWITCH_OTTO_MASTER_SW DPDT': 'Name is too long.'. ERROR(SPMHNI-170): Device 'SW DPDT_3_SWITCH_OTTO_MASTER_SW' has library errors. Unable to transfer to Allegro. #5 ERROR(SPMHNI-176): Device library error detected. ERROR(SPMHNI-189): Problems with the name of device 'SW DPDT_6_SWITCH_OTTO_LIGHTS_SW DPDT': 'Name is too long.'. ERROR(SPMHNI-170): Device 'SW DPDT_6_SWITCH_OTTO_LIGHTS_SW' has library errors. Unable to transfer to Allegro. #6 ERROR(SPMHNI-176): Device library error detected. ERROR(SPMHNI-189): Problems with the name of device 'SW DPDT_3_SWITCH_OTTO_MASTER_DPDT': 'Name is too long.'. ERROR(SPMHNI-170): Device 'SW DPDT_3_SWITCH_OTTO_MASTER_DP' has library errors. Unable to transfer to Allegro. #7 ERROR(SPMHNI-176): Device library error detected. ERROR(SPMHNI-189): Problems with the name of device 'CONNECTOR DB15_DSUBVPTM15_CONNECTOR DB15': 'Name is too long.'. ERROR(SPMHNI-170): Device 'CONNECTOR DB15_DSUBVPTM15_CONNE' has library errors. Unable to transfer to Allegro. #8 ERROR(SPMHNI-176): Device library error detected. ERROR(SPMHNI-189): Problems with the name of device 'CONNECTOR DB9_DSUBVPTM9_CONNECTOR DB9': 'Name is too long.'. ERROR(SPMHNI-170): Device 'CONNECTOR DB9_DSUBVPTM9_CONNECT' has library errors. Unable to transfer to Allegro. #9 ERROR(SPMHNI-175): Netrev error detected. ERROR(SPMHDB-195): Error processing 'M6': Text line is outside of the extents.. ------ Library Paths ------ MODULEPATH = . C:/Cadence/SPB_17.4/share/local/pcb/modules PSMPATH = . symbols .. ../symbols C:/Cadence/SPB_17.4/share/local/pcb/symbols C:/Cadence/SPB_17.4/share/pcb/pcb_lib/symbols C:/Cadence/SPB_17.4/share/pcb/allegrolib/symbols C:/Cadence/SPB_17.4/share/pcb/pcb_lib/symbols PADPATH = . symbols .. ../symbols C:/Cadence/SPB_17.4/share/local/pcb/padstacks C:/Cadence/SPB_17.4/share/pcb/pcb_lib/symbols C:/Cadence/SPB_17.4/share/pcb/allegrolib/symbols C:/Cadence/SPB_17.4/share/pcb/pcb_lib/symbols ------ Summary Statistics ------ #10 Run stopped because errors were detected netrev run on Dec 14 18:54:25 2021 DESIGN NAME : '70055R2' PACKAGING ON Nov 2 2021 14:32:04 COMPILE 'logic' CHECK_PIN_NAMES OFF CROSS_REFERENCE OFF FEEDBACK OFF INCREMENTAL OFF INTERFACE_TYPE PHYSICAL MAX_ERRORS 500 MERGE_MINIMUM 5 NET_NAME_CHARS '#%&()*+-./:=>?@[]^_`|' NET_NAME_LENGTH 24 OVERSIGHTS ON REPLACE_CHECK OFF SINGLE_NODE_NETS ON SPLIT_MINIMUM 0 SUPPRESS 20 WARNINGS ON 10 errors detected No oversight detected No warning detected cpu time 0:00:27 elapsed time 0:00:00 Full Article
i Allegro PCB Design Link issue By community.cadence.com Published On :: Wed, 15 Dec 2021 09:02:56 GMT Hi All I followed tutorial video below for using Design link https://www.youtube.com/watch?v=f9JmFF8lqA0 and I followed the video with embedded board design file which should be same one on video I did every set. but at 2:55 of video, Steve have the tabs of both design names on top of Constraint Manager in video but my one didn't exist them which one would be different? there was some comment on command windows but I think they would not be problem here regard Full Article
i Allegro 17.4 always reports new files as created in 17.2 By community.cadence.com Published On :: Wed, 15 Dec 2021 22:17:58 GMT Hello. I am using Cadence 17.4 tools. When I open a package symbol (.dra) or board file (.brd) in Allegro that was created in an older version of the tool I get a message like this one (as expected): "The design created using release 17.2 will be updated for compatibility with the current software..." If I create a symbol or board file from scratch in the 17.4 tool then open it later, I get the same message. (always referring to version 17.2 which is the previous version I was using here). So far this has not caused me any problems, but I would like to understand why it is doing this in case I have something setup incorrectly. I only have version 17.4 installed. I am not exporting to a downrev version when I save (i.e. not using File->Export->Downrev design…) and in User Preferences->Drawing I don’t have anything selected for database_compatibility_mode. What else might I check? FYI here is the tool version information that I see after selecting Help->About Symbol: OrCAD PCB Designer Standard 17.4-2019 S012 [10/26/2020] Windows SPB 64-bit Edition Thanks -Jason Full Article
i How to magnify a board on a film view By community.cadence.com Published On :: Thu, 16 Dec 2021 17:36:00 GMT I have a small board that is not readable even though the document is 11' x 17'. Is there a way I could expand/magnify the board along with the components on them to make them legible? I have created a new film and is displaying the bottom and top side of the board but the board is too small and the components are not legible. Perhaps there is a way to upscale it or expand it?Please note I have other stuff in the document that I am not showing , notes and other things, and I am trying to make just the boards look bigger in some way.I do have a PDF image of the same file where the board appears to be MUCH bigger and is fully legible and I am trying to match that. Thank you all. Full Article
i Create bounding shape for arcs By community.cadence.com Published On :: Mon, 20 Dec 2021 17:23:09 GMT When using Shape > Create Bounding Shape on an arc, the outer side works well, but on the inner side it just draws a straight line from the begging to the end of the curve. Is anyone aware of a fix for this? I'm attaching a picture as an example, it works great on lines. Full Article
i No windows cascading in OrCAD Capture 17.4 By community.cadence.com Published On :: Tue, 21 Dec 2021 08:02:37 GMT Hello All, I'm a novice to this forum and probably this subject has been already discussed here. My company has purchased OrCAD Capture 17.4 tools that have a new GUI if compared to my earlier used OrCAD Capture 9.2. I have been using Capture 9.2 for ~18 years and its GUI is really convenient. The GUI of 17.4 looks to be a modern one with new icons and really has improved features and new capabilities. However, my main complain about GUI 17.4 is that the schematic windows cannot be cascaded. Although they can be set floating, this is even more annoying because all toolbars remain in the Capture window and when you select a tool, the Capture window pops over already open schematic window and you need a lot of useless extra clicks to return back to the currently edited schematic page. I always used cascading of schematic windows before because my complex designs includes many pages, not speaking about the library windows that are typically open simulatneously. My view is that the lack of CASCADING in Capture GUI 17.4 is critical and unacceptable for complex projects, and I would very highly appreciate if the Cadence guys will return back the CASCADING capability for schematic pages. In case this will be done, this will make the GUI really great and comfortable to use. Does anybody have opinion on this issue? Many thanks, Pavel Full Article
i Version upgrade 17.2 to 17.4 - Cadance orcad capture By community.cadence.com Published On :: Tue, 21 Dec 2021 10:49:08 GMT hello, We have a number of workstations with version 17.2 that work on a floating license server We want to know if it can be upgraded to version 17.4 If so, should the floating license server be upgraded as well? In addition, how can you know where the license was purchased from? Thanks! Full Article
i Sense line and decoupling capacitors By community.cadence.com Published On :: Thu, 23 Dec 2021 08:16:10 GMT Hello, A mybe silly question came to my mind: When routing sense lines, is it better to hav them as close as possible to DUT or afer the decoupling capacitors ? Force in red, sense in purple. Best way is 1 or 2 ? Thanks in advance and Merry Christmas to everybody ! Full Article
i "net logic" question By community.cadence.com Published On :: Thu, 23 Dec 2021 22:52:28 GMT hello: i use the command "net logic" to change/assign the net name of the pins but the command can be used for only one pin at a time. is there a way to change/assign the same net name on 100 pins all at once? i have a daisy chain design so i need to assign one net name for 100s of pins. ======== thank you david, i was able to do it. i am writing this section because i can not reply to your comment. Full Article
i UI issues of PCB Environment Editor 17.4 By community.cadence.com Published On :: Sun, 26 Dec 2021 14:04:11 GMT Hi, I found that under the Dark Theme of PCB Environment Editor 17.4, the window background is not all dark, resulting in unclear text display。 As shown in the figure below: Full Article
i Noise summary data per sub-block in Maestro output expressions By community.cadence.com Published On :: Tue, 22 Oct 2024 21:56:24 GMT Hi, I have a question about printing noise summary via maestro output expressions. How can I print noise data using output expressions, for multiple levels of the hierarchy? I have found this article which describe the procedure using ocnGenNoiseSummary() function: https://support.cadence.com/apex/ArticleAttachmentPortal?id=a1Od0000007MViHEAW&pageName=ArticleContent I see also Andrew Beckett referring to the above mentioned article as a solution to a similar question: community.cadence.com/.../noise-summary-per-instance However, this seems to work only if I'm to extract noise data from a single level of hierarchy. If I have the output expression "ocnGenNoiseSummary(2 ?result 'hbnoise)", it will generate a "noisesummary" directory under results directory for a hierarchy level of 2. If I am to extract data from various hierarchy levels, I should be able to generate multiple noise summary directories, such as noisesummary1, noisesummary2 where they correspond to "ocnGenNoiseSummary(1 ?result 'hbnoise)" & "ocnGenNoiseSummary(2 ?result 'hbnoise)", respectively. However this does not seem to be possible. Can you please advice? Thanks. My Cadence version: IC23.1-64b.ISR7.27 BR, Denizhan Karaca Full Article
i Display Resource Editor: Different Colors for Schematic and Layout Axis By community.cadence.com Published On :: Wed, 23 Oct 2024 06:30:07 GMT Hi In the environment I'm currently working, axes are shown for schematic, symbol, and layout views.For schematics and symbols, I'd prefer a dim gray, such that the axes are just visible but not dominant. For the layout, I'd prefer a brighter color. Is there a way to realize this? So far when I change the color of the 'axis' layer in the display resource editor, the axes in all three views get changed together: Thanks very much for your input! Full Article
i Netlisting error when doing parametric sweep on transient simulation By community.cadence.com Published On :: Wed, 23 Oct 2024 10:13:32 GMT Dear all, I defined two design variables in ADE Assembler, say V1 and V2, that define the voltage 1 and voltage 2 of a "vpulse" voltage source in my schematic. Then, I define V1 = 1.0, and V2 = 2.0, run a transient simulation, and everything is as expexcted. The source provides pulses between 1.0 V and 2.0 V. Next, I set V1 = 1.0:0.5:1.5, thereby creating a parametric sweep with 1.0 V and 1.5 V for V1. I keep V2 at 2.0 V. Then the simulation fails, and all I get is "netl err" in my Output Expressions and an error message that the results directory does not exist and nothing can be plotted: This is reasonable, as the results directory is deleted on starting a new simulation, and as there is no simulation result, none of my output expressions can be plotted. WARNING (OCN-6040): The specified directory does not exist, or the directory does not contain valid PSF results. Ensure that the path to the directory is correct and the directory has a logFile and PSF result files.WARNING (ADE-1065): No simulation results are available.ERROR (WIA-1175): Cannot plot waveform signals because no waveform data is available for plotting.One of the possible reasons can be that 'Save' check box for these signals are not selected in the Outputs Setup pane. Ensure that these check boxes are selected before you run the simulation. Normally, this kind of para,metric sweep is not a problem, I have done this many times before. There must be something special in THIS PARTICULAR test bench or simulator setup. The trouble is, I don't get any useful error messages. Does anyone know what might be the problem here OR where to find useful information to investigate further (log files stored somewhere)? Thank you! Regards, Volker P.S. Using Corners instead does not help either. Running it through all values by hand works, though. Full Article
i Import LEF file failed due to layermap By community.cadence.com Published On :: Thu, 24 Oct 2024 15:58:52 GMT Hi, I have a LEF file with simple definitions of pad design which uses M8, M9, and AP layers. However, I failed to import the design with CIW > Import > LEF... as I encountered "ERROR: (OALEFDEF-90019): Ignoring the line 30 in the layer map file ... as it contains a syntax error. Each entry in the layer map file must have two values, LEFLayerName and OALayerNumber separated by a blank space." All lines in the file report the same OALEFDEF-90019 error.The tech.layermap file looks like this:# techLayer techPurpose stream# dataType ref drawing 0 0 DNW drawing 1 0 PW drawing 2 0 Full Article
i A problem with setup when Monte Carlo simulation starts By community.cadence.com Published On :: Thu, 24 Oct 2024 17:50:42 GMT Hi, When I try to run Monte Carlo it gives me a 3 items message for possible failure: 1. It says the machine selected in the current job setup policy isnot reachable 2. The Cadence hierarchy is not detected, not installed properly. or 3. Job start script (with a path and a name like swiftNetlistService#) is not found on the remote machines. Any recommendation on how to fix this? Full Article
i New CDF creation and callback By community.cadence.com Published On :: Sun, 27 Oct 2024 11:35:08 GMT I need to add a new CDF parameter called "mag" to symbols in a given library using skill script in which the symbol size can be controlled and call back it each time this library is used so that all the symbols are updated. Full Article
i Cannot access individual noise contributions using SpectreMDL By community.cadence.com Published On :: Tue, 29 Oct 2024 12:21:23 GMT I have tried replicating the setup described in a previous post (here), with the proposed solution. The MDL measurements return a value of 0 for all exported result but the first. Using Viva I can actually see the correct value for each contribution. I am using :- Spectre 23.1.0.538.isr10- Viva IC23.1-64b.ISR8.40 What should I do differently? Thanks! ***** test.scs ***** r1 (1 0) res_model l=10e-6 w=2e-6 r2 (2 1) res_model l=15e-6 w=2e-6 vr (2 0) vsource dc=1.0 mag=1 model res_model resistor rsh=100 kf=1e-20*exp(dkf) parameters dkf=0 statistics { process { vary dkf dist=gauss std=0.5 } } noi (1 0) noise freq=1 /***** test.mdl *****/ alias measurement noi_test { run noi; export real noi_total=noi_test:out; export real r1_total=r1:total; export real r1_flicker=r1:fn; export real r1_thermal=r1:rn; export real r2_total=r2:total; export real r2_flicker=r2:fn; export real r2_thermal=r2:rn; } run noi_test **** test.measure **** Measurement Name : noi_testAnalysis Type : noisenoi_total = 6.9282e-06 r1_flicker = 0 r1_thermal = 0 r1_total = 0 r2_flicker = 0 r2_thermal = 0 r2_total = 0 Full Article
i Error using probe terminal for dspf stb analysis By community.cadence.com Published On :: Wed, 30 Oct 2024 10:02:43 GMT IC 23.1-64b.ISR8.40 Hi all, I'm trying to run an stb analysis in a dspf extracted view via Probe terminal. The instance exist in the dspf and I already prepended the X that is placed in the dspf extraction. Spectre complains with the following error: Error found by spectre during STB analysis `stb'. ERROR (SPECTRE-16408): The probe parameter must be specified to perform stability analysis.Analysis `stb' was terminated prematurely due to an error. What is missing here? Full Article
i Config sweep View in Tests By community.cadence.com Published On :: Wed, 30 Oct 2024 10:28:38 GMT Hi all, I have a question regarding how to sweep the config view without using a global variable. I’d like to set a different config view for each test, and I'm trying to avoid using corners or plan. Any suggestions on how to achieve this? Thanks in advance for your help! Best,MooH Full Article
i How can I place stacked vias with the size exact same cut width without metals around? By community.cadence.com Published On :: Wed, 30 Oct 2024 12:40:16 GMT How can I place stacked vias with the size exact same cut width without metals around?As the red part only in the image below? Full Article
i Change code in veriloga view from external program By community.cadence.com Published On :: Wed, 30 Oct 2024 15:31:02 GMT For reasons too complicated to go into here, I need to generate the code for a veriloga view from a outside the normal Verilog-A editor. I would start with an "empty" veriloga view generated from the symbol in the normal way so I get the port order correct, then use external code to provide "guts" of the veriloga view by overwriting the generated code. My understanding is that and code changes made external to the normal flow do not get picked up by Cadence - the Verilog-A code gets read at design time, not at netlist time. Would simply forcing a check and save of the veriloga view after the code is modified fix that problem? Or is there an easier way to incorporate externally generated Verilog-A code? Full Article
i Author and library name in sheet border By community.cadence.com Published On :: Thu, 31 Oct 2024 10:05:54 GMT Dear community We would like to have more minimalistic and customized sheet borders for our schematics. I used this guide to create a starting point. Essentially, I made a copy of the US_8ths library and modified the Title symbol to look something like that: Problem 1 The variable ilInst~>libName points to the library of the sheet border symbols, not to the library of the schematic. How do I need to modify this field in order to see the library name of the schematic where the border is instantiated? Problem 2 The function CCSgetCreator() was taken from here. This solution does not seem to work with our management toll (we use VersIC); the function always returns nil as value. What is the simplest way to display the name of the user that created the schematic? A custom field that could be filled manually would also do the job for us; it doesn't need to be something that automatically fetches data from a database system. Thanks for any input. Full Article
i How to use PSpice library in Virtuoso/Spectre? By community.cadence.com Published On :: Thu, 31 Oct 2024 14:02:01 GMT I want to use PSpice model (download from TI) in Virtuoso , but it can not work. Please help me to check the error message, Thanks ADE-> Setup-> simulation files->Pspice Files /TPS628502-Q1_TRANS.LIB Parse error before token ']' in expression '[[STEADY_STATE]*0.6]'. If '[[STEADY_STATE]*0.6]' is a spice expression, quotes are required for the expression. ERROR(SFE-46): An instance of 'TPS628502-Q1_TRANS' can have at most 8 terminals (but has 9). *****************************************************************************.SUBCKT TPS628502-Q1_TRANS COMP_FSET EN FB GND PG SW SYNC_MODE VIN + PARAMS: STEADY_STATE=0 V_U9_V45 U9_N16725824 0 5E_U9_ABM22 U9_N16725392 0 VALUE { V(FREQ)*1e-12 }X_U9_U161 U9_N16849713 U9_N16846056 one_shot PARAMS: T=20 Full Article
i Verilog-A: Can I ignore WARNING (VACOMP-1047) By community.cadence.com Published On :: Thu, 31 Oct 2024 22:26:29 GMT I need to include Verilog-A files which live outside the Cadence ecosystem (i.e., they are not in veriloga views but rather are just text files) into a veriloga view. These external modules are not compatible with OA (parametized port widths) so I can't put them into cellviews and hook them together using schematics. Example: I have a cellview "test" which has a symbol and veriloga view. I have three "externaI" modules mod1 (inside an external file mod1.va), mod2 (inside an external file mod2.va), and mod3 (inside an external file mod3.va). I instantiate one instance of each module in "module test". The three modules have some parametized ports which are interconnected by parameterized signals p1 and p2. These two signals are strictly local to the module. At the bottom of the module I use "`include mod1.va", "`mod2.va", etc. When I check and save test->veriloga it checks all the included modules as well as the "test" module. However, I get a warning: Warning from spectre during AHDL compile. WARNING (VACOMP-1047): The Verilog-A file contains more than one module definition. ADE can process only one module per Verilog-A file. Put only one module in each Verilog-A file so that ADE can identify pin names, directions, and hierarchy within each separate module. Is this just a SUGGESTION that I can safely ignore, or are my included modules going to be ignored? Full Article
i Xcelium/Simvision/xrun running very slow (waiting for SimVision/Verisium Debug to connect...) By community.cadence.com Published On :: Fri, 01 Nov 2024 10:44:24 GMT Hello,I would like to use the simulation software xrun/simvision that comes with XCELIUM. We are currently using classroom licenses and want to disable all ip addresses on the student pcs except the license server ip. We want to make sure that students cannot copy confidential data from the Cadence tools.Problem:When I launch the xrun simulation while all ip addresses are blocked, it starts but the performance is very slow. The GUI starts after 5 minutes and the simulation is ready after 10 minutes. The interesting thing is that when I enable all blocked ip addresses, everything works at a reasonable speed. Terminal Output (execution without internet connection): xrun -gui design.vhd waiting for SimVision/Verisium Debug to connect...Is there a way to run the simulation tools without an Internet connection? Or can you give me the ip addresses that are used by the simulation tools so that I can enable only those specific ips?Regards,Max Full Article
i Transient Simulation waveform abnormal By community.cadence.com Published On :: Sat, 02 Nov 2024 14:23:52 GMT Hello Everybody Recently, I want to design a high output Power Amplifier at 2.4GHz using TSMC 1P6M CMOS Bulk Process. I use its nmos_rf_25_6t transistor model to determine the approximate mosfet size I use the most common Common-Source Differential Amplifier topology with neutralizing capacitor to improve its stability and power gain performance Because I want to output large power, the size of mosfet is very large, the gate width is about 2mm, when I perform harmonic balance analysis, everything is alright, the OP1dB is about 28dBm (0.63Watt) But When I perform Transient simulation, the magnitude of voltage and current waveform at the saturation point is too small, for voltgae, Vpeaking is about 50mV, for current, Ipeaking is about 5mA I assume some reasons: the bsim4 model is not complete/ the virtuoso version is wrong (My virtuoso version is IC6.1.7-64b.500.21)/the spectre version is wrong (spectre version is 15.1.0 32bit)/the MMSIM version is wrong/Transient Simulation setting is wrong (the algorithm is select gear2only, but when I select other, like: trap, the results have no difference), the maxstep I set 5ps, minstep I set 2ps to improve simulation speed, I think this step is much smaller than the fundamental period (1/2.4e9≈416ps) I have no idea how to solve this problem, please help me! Thank you very very much! Full Article
i How to get maximum value of s11 Trace By community.cadence.com Published On :: Mon, 04 Nov 2024 14:04:46 GMT Hello i did a sp-Analysis and now i want to extract the maximum value of the s11 trace and the corresponding frequency. I already tried ymax() in the calculator but i am suspecting it only works on transient Signals. Full Article
i Characterization of Full adder that use transmission gates using liberate By community.cadence.com Published On :: Mon, 04 Nov 2024 17:59:38 GMT Hello,I'm trying to characterize a full adder that use transmission gate.Unfortunately, the power calculation are wrong for the cell are always negative.Is there any method or commands that can can help in power calculation or add the power consumption by the input pins to the power calculation ?Another question, Is liberate support the characterization or transmission gate cells as standard cells or I should use liberate AMS for these type of cells ?Thanks in advance,Tareq Full Article
i error when generating snp files from a variable By community.cadence.com Published On :: Tue, 05 Nov 2024 11:22:54 GMT Hello everyone, I have a testbench for generating s2p files from a SP simulation that was working until few months ago. Today I have reopened (w/o making changes that I am aware of) and I get the error as shown below: first I show the testbench settings: notice how the s2p generation is disabled: the field "file" is left blank in the corner I defined some parameters, "filename" is the word that is suppose to generate the name for the s2p. where the two variables are defined as follows And now the output log: spectre.out file gives the following error:When clicking on the error message at "9", the input.scs file opens up and the line 9 gets highlighted in greennow, so far I understood that the problem seem to be related tom the "pathcds" variable, but I really don't understand what the error message here means, since I don't see any error in the input.scs file by the way - if for instance I define the variable "filename" as shown below, then I get no errors: thanksTommaso Full Article
i Colorcoding for low cpk in Yield-View in Assembler By community.cadence.com Published On :: Tue, 05 Nov 2024 13:06:47 GMT Hi, I'm searching for a way to get a quick overview of too low cpk-values after a montecarlo sim. The non-MC results have the spec and thus the easy/understandable red/green/(yellow) colorcoding, but for MC sims I don't get a highlight for high variations inside the limits. Is this possible (besides copying each expression into avg()+3*std()) and ..-..)? It would be really handy to scan through finished sims... (My final application is then to export the table for my reports and documentation...) Regards, leo Full Article
i ddt VerilogA usage By community.cadence.com Published On :: Thu, 07 Nov 2024 13:14:08 GMT Hi, reading Verilog®-A Language Reference I found this description of ddt function I don't understand: Use the time derivative operator to calculate the time derivative of an argument. ddt( input [ , abstol | nature ] ) input is a dynamic expression. abstol is a constant specifying the absolute tolerance that applies to the output of the ddt operator. Set abstol at the largest signal level that you consider negligible. nature is a nature from which the absolute tolerance is to be derived. Can anyone explain how abstol and nature are defined? how using them? an example would be really appreciated. Thanks Andrea Full Article
i Force virtuoso (Layout XL) to NOT create warning markers in design By community.cadence.com Published On :: Sat, 09 Nov 2024 08:54:31 GMT Hi I have a rather strange question - is there a way to tell layout XL to NOT place the error/warning markers on a design when I open a cell? I do a lot of my layout by using arrays from placed instances and create mosaics that completely ignore the metadata that Layout XL uses with its bindings with schematic (and instances get deleted etc. but I do like using it to generate all my pins etc.) and it's just really annoying when I open a design that I know is LVS clean and since the connectivity metadata is all screwed up (because I did not use it to actually complete the layout) I have a design that's just blinking at me at every gate, source and drain. I typically delete them at the high level heirarchically but the second I go in and modify something and come back up it places all of them again. I know that if I flatten all the p cells it goes away but sometimes it's nice to have that piece of metadata but that's about it. Is there a way to "break" the features of XL like this? I realize what a weird question this is but it's becoming more of an issue since we moved to IC 23 from IC 6 where there is no longer a layout L that I can use free from these annoyances that can't use any of the connectivity metadata. Thanks Chris Full Article
i AMS simvision cannot load big psf.trn By community.cadence.com Published On :: Mon, 11 Nov 2024 18:27:49 GMT Hello all, I have run a simulation with a lot of instnaces extraction and the psf.trn is >= 200 Gb, I tried to load it with simvision and it just breaks. I would like to ask if there is a way to open this file, e.g. if I could read only some time window e.g. from 10us -> 15us. getVersion(t) "sub-version ICADVM20.1-64b.500.34 " XCELIUMMAIN23.03.001 thank you in advance Full Article
i How to Set Up a Config View to Easily Switch Between Schematic and Calibre of DUT for Multiple Testbenches? By community.cadence.com Published On :: Tue, 12 Nov 2024 16:22:53 GMT Hello everyone, I hope you're all doing well. I’ve set up two testbenches (TB1 and TB2) for my Design Under Test (DUT) using Cadence IC6.1.8-64b.500.21 tools, as shown in the attached figure. The DUT has multiple views available: schematic, Calibre, Maestro, and Symbol, and each testbench uses the same DUT in different scenarios. Currently, I have to manually switch between these views, but I would like to streamline this process. My goal is to use a single config view that allows me to switch between the schematic and the extracted (Calibre) views. Ideally, I would like to have a configuration file where making changes once would update both testbenches (TB1 and TB2) automatically. In other words, when I modify one config, both testbenches should reflect this update for a single simulation run. I would really appreciate it if you could guide me on the following: How to create a config view for my DUT that can be used to easily switch between the schematic and extracted views, impacting both TB1 and TB2. Where to specify view priorities or other settings to control which view is used during simulation. Best practices for using a config file in this scenario, so that it ensures consistency across multiple testbenches. Please refer to the attached figure to get a better understanding of the setup I’m using, where both TB1 and TB2 include the same DUT with multiple available views. Thank you so much for your time and assistance! Full Article
i Tagging uvm_errors in waveform file for post-processing By community.cadence.com Published On :: Thu, 08 Feb 2024 11:45:04 GMT Hi, Do anyone know if it's possible in simvision waveform viewer to see a timestamp of where uvm_errors/$errors occurred in a simulation via post-processing? Cheers, Antonio Full Article
i incorrect output of multiplication in jaspergold By community.cadence.com Published On :: Fri, 16 Feb 2024 10:02:22 GMT I want to use jaspergold to formally verify functionality of my custom multiplier. I am computing the expected result using A*B to check against output of my multiplier. Here, A and B are two logic signed operands. However, jaspergold is performing the operation A*B incorrectly. I have reproduced this issue using the attached example. JasperGold compiles and elaborates the module and subsequently runs a formal proof. The tool raises a counterexample to assertion whose screenshot is attached below: I simulated the same example using xrun and it was giving the correct product output in simvision waveform. Please help me resolve this issue. I am using 2023.03 version of Jasper Apps. Thanks and regards Anubhav Agarwal Full Article
i Jasper's elaborate -bbox_i seems to have no effect By community.cadence.com Published On :: Fri, 23 Feb 2024 12:32:52 GMT I'm trying to use Jasper for checking parameter propagation in a large design. I have a list of top-level parameters, each with a HDL path of a module parameter somewhere lower in the hierarchy that's supposed to receive its value from the top-level module. The FPV app seems like an excellent tool for this, but elaborating the entire design in it is extremely time-consuming and memory-intensive. So, I'm trying to black-box everything but the interesting HDL paths. I thought using `elaborate -top dut_module_name -bbox_i * -no_bbox_i inst_foo -no_bbox_i inst_bar (...)` would work, but it doesn't. Jasper just starts flooding the log with warnings from modules that are definitely not on the whitebox list, and eventually dies due to insufficient memory. When I use -bbox_m * it correctly elaborates the top-level module with all of its sub-modules black-boxed. But then the -no_bbox_i switches have no effect. Could anyone suggest a working solution for this use case? Full Article
i UVM Adapter for Pipelined protocols like AHB, AXI etc By community.cadence.com Published On :: Sat, 24 Feb 2024 06:10:18 GMT Hello, I have been running this `uvm_reg_hw_reset_seq` sequence for the AHB protocol. My UVM Adapter looks like: Issue: When I use basic reg.write, my write access are working well, as that is managed by the driver i.e. once adapter gives the packet to the driver, the driver supplies the address and the control signals to the DUT on the first clock cycle and then the write data on the next clock cycle. But when I am performing the read operation, somehow the UVM adapter is reading the data at the same clock cycle where read address + Controls are supplied and this is triggering read failure messages from the `uvm_reg_hw_reset_seq` sequence. What should I modify in the driver/sequencer/adapter so that the UVM adapter can read the data on the next cycle instead of the same clock cycle. Just FYI: The waveforms of the read operation are correct, it is just the Adapter and the `uvm_reg_hw_reset_seq`. The AHB Driver + AHB Monitor is fully proven and verified to be working correctly. Full Article
i Using Xcelium, xrun -nogui option, where are the simulation results By community.cadence.com Published On :: Thu, 29 Feb 2024 18:23:56 GMT I'm completely new to Cadence. I've been able to run a very simple simulation with the -gui option. Simvision opens, I add the variables to the waveform viewer, and press run. All is good. I don't understand the flow when using the -nogui option. It appears that the simulation runs and returns control to the OS. When I launch Simvision, is there a database or file that I can open to display the already-simulated data? My command is of the form: xrun -gui -64bit -sv -access +rwc -top tb_top.sv <src files> Full Article
i Importing ODF to vManager does not update vplan By community.cadence.com Published On :: Tue, 05 Mar 2024 06:20:00 GMT I exported vplan to .odf file in vManager and after editing it I imported it to vManager. The vplan was expected to be synchronized and updated. However, nothing has changed to it. Does anyone know why? Full Article
i UVM debugging: How to save and load signals during an interactive session in Simvision By community.cadence.com Published On :: Thu, 07 Mar 2024 23:18:50 GMT Hello, I am aware of command script .svcf file that saves signals and loads them in while opening Simvision. I am wondering, if there is a way for saving signals while we are in an interactive session and loading them next time when we open Simvision interactively. Any ideas on how to do this? Thank you in advance. Swetha. C Full Article
i Using Vmanager Pre-Script to launch a timed script By community.cadence.com Published On :: Thu, 07 Mar 2024 23:32:05 GMT I would like to send an update about a vmanager regression status x days after the regression has been run. In the current environment, the vmanager regression is creating a new filepath for logs automatically based on regression name/date, so I can't use a cron job to gather logs, as the log location is not known. I tried to use the pre session script to launch a detached shell script that would run after a delay, but when the pre_script runs, it waits until everything is completed before finishing and moving on to starting the regression. Here is the test pre_script I am using: #!/bin/sh echo "pre_script start" delay_script "FIRST" 1nohup delay_script "SECOND" 30 & disowndelay_script "THIRD" 1 echo "pre_script end"exit 0 Here is the test delay_script I am using: #!/bin/sh echo "Starting $1" sleep $2 echo "Ending $1" Here is the script output when run from terminal. After the "pre_script end", I get control back. Here is the script output when run from vmanager. There is no "nohup", and the pre_session phase doesn't complete until all the delay scripts complete. My question is, is there a better way to achieve my goal here? (The goal being to run a script from the vmanager log directory automatically x days after the regression). I think I could use the pre_script to send directory information for an auxiliary cron job to pick up, but I would prefer to not have to have extra cronjobs needed for this. Full Article
i vManager crashes when analyzing multiple sessions simultaneously with a fatal error detected by the Java Runtime Environment By community.cadence.com Published On :: Sat, 16 Mar 2024 04:34:41 GMT When analyzing multiple sessions simultaneously Verisium Manager crashed and reported below error messages: # A fatal error has been detected by the Java Runtime Environment: # # SIGSEGV (0xb) at pc=0x00007efc52861b74, pid=14182, tid=18380 # # JRE version: OpenJDK Runtime Environment Temurin-17.0.3+7 (17.0.3+7) (build 17.0.3+7) # Java VM: OpenJDK 64-Bit Server VM Temurin-17.0.3+7 (17.0.3+7, mixed mode, sharing, tiered, compressed oops, compressed class ptrs, g1 gc, linux-amd64) # Problematic frame: # C [libucis.so+0x238b74] ...... For more details please refer to the attached log file "hs_err_pid21143.log". Two approaches were tried to solve this problem but neither has worked. Method.1: Setting larger heap size of Java process by "-memlimit" options.For example "vmanager -memlimit 8G". Method.2: Enlarging stack memory size limit of the Coverage engine by setting "IMC_NATIVE_STACKSIZE" environment variable to a larger value. For example "setenv IMC_NATIVE_STACKSIZE 1024000" According to "hs_err_pid*.log" it is almost certain that the memory overflow triggered Java's CrashOnOutOfMemoryError and caused Verisium Manager to crash. There are some arguments about memory management of Java like "Xms, Xmx, ThreadStackSize, Xss5048k etc" and maybe this problem can be fixed by setting these arguments during analysis. However, how exactly does Verisium Manager specify these arguments during analysis? I tried to set them by the form of setting environment variables before analysis but it didn't work in analysis and their values didn't change. Is there something wrong with my operation or is there a better solution? Thank you very much. Full Article
i explain/correct my understanding between average/covered in imc metrics By community.cadence.com Published On :: Wed, 17 Apr 2024 05:36:41 GMT I'm working on the code coverage. Doing a metrics analysis by default we see overall average grade and overall covered. But when i do a block analysis on an instance i see overall covered grade, code covered grade, block covered grade, statement covered grade, expression covered grade, toggle covered grade. As I dont know the difference I started to read the IMC user guide and came to know there are 3 things we come across while doing a code coverage local, covered, average From my understanding local - child instances metrics doesnt reach the parent level. For example, we have an instance Q and its sub instances like Q.a, Q.b. Block Local grade of Q can be 100% even when its instances Q.a and Q.b a block local grades isnt at 100%. In the attached image there is formula The key difference between average and covered is the weights. Average : Mathematically taking the above scenario where Q.a, and Q.b has 10 blocks each. Q.a has covered 8 blocks and q.b has covered 2 blocks. Now if we take the normal average it should be total covered/ totatl number = 8+2/10+10 yielding 50%. But when we add weights saying Q.a is 70% and Q.b is 30% the new number would be (8*0.7+2*0.3) / (10*0.7+10*0.3) resulting 62%. Because of the weights we see 12% bump. Covered: there is no role of weights. Among these 3 metrics i've changed my default view to this in the image to get more realistic picture when i do analyze metrics. Do you guys agree with the approach? Full Article
i Parameterizing an Instance By community.cadence.com Published On :: Wed, 24 Apr 2024 16:03:12 GMT Hi,I want to parameterized width and length of a NMOS, but it ignore it and I face this error:*WARNING* Value input must be a number - setting back to previous value.Does anybody know how I can fix this issue?Thanks Full Article