at Crystal structure and Hirshfeld-surface analysis of an etoxazole metabolite designated R13 By journals.iucr.org Published On :: The crystal structure of a metabolite of the insecticide/acaricide etoxazole, designated R13 is presented along with a Hirshfeld surface analysis of intermolecular interactions present in the crystal structure. Full Article text
at Crystal structure, Hirshfeld surface analysis, DFT and molecular docking studies of ethyl 5-amino-2-bromoisonicotinate By journals.iucr.org Published On :: Theoretical and experimental structural studies of the title compound were undertaken using X-ray and DFT methods. The interactions present in the crystal were analyzed using Hirshfeld surface and MEP surface analysis. Docking studies with a covid-19 main protease (PDB ID: 6LU7) as the target receptor indicate that the synthesized compound may be a potential candidate for pharmaceutical applications. Full Article text
at Crystal structure of 1,10-phenanthrolinium violurate violuric acid pentahydrate By journals.iucr.org Published On :: The crystal structure of the co-crystal salt solvate 1,10-phenanthrolinium violurate violuric acid pentahydrate features a tri-periodic hydrogen-bonded network with the violurate and violuric acid residues each assembled into tapes and the phenanthrolinium cations residing in channels. Full Article text
at Crystal structure of a solvated dinuclear CuII complex derived from 3,3,3',3'-tetraethyl-1,1'-(furan-2,5-dicarbonyl)bis(thiourea) By journals.iucr.org Published On :: In the title compound, [Cu2(L)2]·2CH2Cl2, the CuII ions coordinate two (S,O)-chelating aroylthiourea moieties of doubly deprotonated furan-2,5-dicarbonylbis(N,N-diethylthiourea) (H2L) ligands. The coordination geometry of the metal centers is best described as a flat isosceles trapezoid with a cis arrangement of the donor atoms. Full Article text
at Crystal structure of N-terminally hexahistidine-tagged Onchocerca volvulus macrophage migration inhibitory factor-1 By journals.iucr.org Published On :: N-terminally hexahistidine-tagged O. volvulus macrophage migration inhibitory factor-1 has a unique jellyfish-like structure with the prototypical macrophage migration inhibitory factor trimer as the `head' and a C-terminal extension as the `tail'. Full Article text
at A micro-beamstop with transmission detection by fluorescence for scanning-beam synchrotron scattering beamlines By journals.iucr.org Published On :: 2024-10-29 Quantitative X-ray diffraction approaches require careful correction for sample transmission. Though this is a routine task at state-of-the-art small-angle X-ray scattering (SAXS), wide-angle X-ray scattering (WAXS) or diffraction beamlines at synchrotron facilities, the transmission signal cannot be recorded concurrently with SAXS/WAXS when using the small, sub-millimetre beamstops at many X-ray nanoprobes during SAXS/WAXS experiments due to the divergence-limited size of the beamstop and the generally tight geometry. This is detrimental to the data quality and often the only solution is to re-scan the sample with a PIN photodiode as a detector to obtain transmission values. In this manuscript, we present a simple yet effective solution to this problem in the form of a small beamstop with an inlaid metal target for optimal fluorescence yield. This fluorescence can be detected with a high-sensitivity avalanche photodiode and provides a linear counter to determine the sample transmission. Full Article text
at AnACor2.0: a GPU-accelerated open-source software package for analytical absorption corrections in X-ray crystallography By journals.iucr.org Published On :: 2024-11-04 Analytical absorption corrections are employed in scaling diffraction data for highly absorbing samples, such as those used in long-wavelength crystallography, where empirical corrections pose a challenge. AnACor2.0 is an accelerated software package developed to calculate analytical absorption corrections. It accomplishes this by ray-tracing the paths of diffracted X-rays through a voxelized 3D model of the sample. Due to the computationally intensive nature of ray-tracing, the calculation of analytical absorption corrections for a given sample can be time consuming. Three experimental datasets (insulin at λ = 3.10 Å, thermolysin at λ = 3.53 Å and thaumatin at λ = 4.13 Å) were processed to investigate the effectiveness of the accelerated methods in AnACor2.0. These methods demonstrated a maximum reduction in execution time of up to 175× compared with previous methods. As a result, the absorption factor calculation for the insulin dataset can now be completed in less than 10 s. These acceleration methods combine sampling, which evaluates subsets of crystal voxels, with modifications to standard ray-tracing. The bisection method is used to find path lengths, reducing the complexity from O(n) to O(log2 n). The gridding method involves calculating a regular grid of diffraction paths and using interpolation to find an absorption correction for a specific reflection. Additionally, optimized and specifically designed CUDA implementations for NVIDIA GPUs are utilized to enhance performance. Evaluation of these methods using simulated and real datasets demonstrates that systematic sampling of the 3D model provides consistently accurate results with minimal variance across different sampling ratios. The mean difference of absorption factors from the full calculation (without sampling) is at most 2%. Additionally, the anomalous peak heights of sulfur atoms in the Fourier map show a mean difference of only 1% compared with the full calculation. This research refines and accelerates the process of analytical absorption corrections, introducing innovative sampling and computational techniques that significantly enhance efficiency while maintaining accurate results. Full Article text
at Grazing-incidence small-angle neutron scattering at high pressure (HP-GISANS): a soft matter feasibility study on grafted brush films By journals.iucr.org Published On :: 2024-11-04 Grazing-incidence small-angle neutron scattering (GISANS) under pressure (HP-GISANS) at the solid (Si)–liquid (D2O) interface is demonstrated for the pressure-induced lateral morphological characterization of the nanostructure in thin (<100 nm) soft matter films. We demonstrate feasibility by investigating a hydrophobic {poly[(2,2,3,3,4,4,5,5-octafluoro)pentyl methacrylate]} (POFPMA)–hydrophilic {poly[2-(dimethylamino)ethyl methacrylate]} (PDMAEMA) brush mixture of strong incompatibility between the homopolymers, anchored on Si, at T = 45°C for two pressures, P = 1 bar and P = 800 bar. Our GISANS results reveal nanostructural rearrangements with increasing P, underlining P-induced effects in tethered polymer brush layers swollen with bulk solvent. Full Article text
at Animations, videos and 3D models for teaching space-group symmetry By journals.iucr.org Published On :: 2024-10-16 A series of animations, videos and 3D models that were developed, filmed or built to teach the symmetry properties of crystals are described. At first, these resources were designed for graduate students taking a basic crystallography course, coming from different careers, at the National Autonomous University of Mexico. However, the COVID-19 pandemic had the effect of accelerating the generation of didactic material. Besides our experience with postgraduate students, we have noted that 3D models attract the attention of children, and therefore we believe that these models are particularly useful for teaching children about the assembled arrangements of crystal structures. Full Article text
at Position-independent product increase rate in a shaker mill revealed by position-resolved in situ synchrotron powder X-ray diffraction By journals.iucr.org Published On :: 2024-11-08 We investigated the position and time dependence of a mechanochemical reaction induced by ball milling using in situ synchrotron powder X-ray diffraction with changing X-ray irradiation position. The mechanochemical reduction of AgCl with Cu was monitored in situ with the X-rays incident at two different vertical positions on the jar. Our previously developed multi-distance Rietveld method was applied to analyze the in situ diffraction data with a 1 min resolution. Both the vertical and the horizontal sample positions were determined using the sample-to-detector distances from the in situ data. Position dependence was found in the powder spreading and induction time. We reveal that the increase rate of the product is independent of the sample position when measured with a 1 min time resolution, confirming the validity of in situ monitoring of part of the space in a milling jar for a gradual mechanochemical reaction. Full Article text
at Small-angle scattering and dark-field imaging for validation of a new neutron far-field interferometer By journals.iucr.org Published On :: 2024-11-08 The continued advancement of complex materials often requires a deeper understanding of the structure–function relationship across many length scales, which quickly becomes an arduous task when multiple measurements are required to characterize hierarchical and inherently heterogeneous materials. Therefore, there are benefits in the simultaneous characterization of multiple length scales. At the National Institute of Standards and Technology, a new neutron far-field interferometer is under development that aims to enable a multi-scale measurement combining the best of small-angle neutron scattering (SANS) and neutron imaging and tomography. Spatially resolved structural information on the same length scales as SANS (0.001–1 µm) and ultra-small-angle neutron scattering (USANS, 0.1–10 µm) will be collected via dark-field imaging simultaneously with regular attenuation radiography (>10 µm). The dark field is analogous to the polarization loss measured in spin-echo SANS (SESANS) and is related to isotropic SANS through a Hankel transform. Therefore, we use this close relationship and analyze results from SANS, USANS, SESANS and dark-field imaging of monodisperse spheres as a validation metric for the interferometry measurements. The results also highlight the strengths and weaknesses of these neutron techniques for both steady-state and pulsed neutron sources. Finally, we present an example of the value added by the spatial resolution enabled by dark-field imaging in the study of more complex heterogeneous materials. This information would otherwise be lost in other small-angle scattering measurements averaged over the sample. Full Article text
at Exploiting Friedel pairs to interpret scanning 3DXRD data from complex geological materials By journals.iucr.org Published On :: 2024-11-08 The present study introduces a processing strategy for synchrotron scanning 3D X-ray diffraction (s3DXRD) data, aimed at addressing the challenges posed by large, highly deformed, polyphase materials such as crystalline rocks. Leveraging symmetric Bragg reflections known as Friedel pairs, our method enables diffraction events to be precisely located within the sample volume. This method allows for fitting the phase, crystal structure and unit-cell parameters at the intra-grain scale on a voxel grid. The processing workflow incorporates several new modules, designed to (i) efficiently match Friedel pairs in large s3DXRD datasets containing up to 108 diffraction peaks; (ii) assign phases to each pixel or voxel, resolving potential ambiguities arising from overlap in scattering angles between different crystallographic phases; and (iii) fit the crystal orientation and unit cell locally on a point-by-point basis. We demonstrate the effectiveness of our technique on fractured granite samples, highlighting the ability of the method to characterize complex geological materials and show their internal structure and mineral composition. Additionally, we include the characterization of a metal gasket made of a commercial aluminium alloy, which surrounded the granite sample during experiments. The results show the effectiveness of the technique in recovering information about the internal texture and residual strain of materials that have undergone high levels of plastic deformation. Full Article text
at The effects of low boron incorporation on the structural and optical properties of BxGa1−xN/SiC epitaxial layers By journals.iucr.org Published On :: 2024-11-04 BGaN epilayers with boron contents up to 5.6% were grown on SiC substrates by metal–organic chemical vapor deposition. The effects of boron incorporation on the structural and optical properties were studied by high-resolution X-ray diffraction (XRD), atomic force microscopy (AFM), Raman spectroscopy and photoluminescence (PL) spectroscopy. XRD reciprocal-space maps around the symmetric 0002 and asymmetric 11 {overline 2} 4 reflections allowed evaluation of the lattice constants and lattice mismatch with respect to the underlying substrate. XRD rocking curves and AFM measurements indicated the mosaic microstructure of the epilayer. The impact of boron content on crystallite size, tilt and twist is evaluated and the correlation with threading dislocation density is discussed. The deterioration of optical properties with increasing boron content was assessed by Raman and PL spectroscopy. Full Article text
at Improving the reliability of small- and wide-angle X-ray scattering measurements of anisotropic precipitates in metallic alloys using sample rotation By journals.iucr.org Published On :: 2024-11-04 Nanometric precipitates in metallic alloys often have highly anisotropic shapes. Given the large grain size and non-random texture typical of these alloys, performing small- and wide-angle X-ray scattering (SAXS/WAXS) measurements on such samples for determining their characteristics (typically size and volume fraction) results in highly anisotropic and irreproducible data. Rotations of flat samples during SAXS/WAXS acquisitions are presented here as a solution to these anisotropy issues. Two aluminium alloys containing anisotropic precipitates are used as examples to validate the approach with a −45°/45° angular range. Clear improvements can be seen on the SAXS I(q) fitting and the consistency between the different SAXS/WAXS measurements. This methodology results in more reliable measurements of the precipitate's characteristics, and thus allows for time- and space-resolved measurements with higher accuracy. Full Article text
at Mapping domain structures near a grain boundary in a lead zirconate titanate ferroelectric film using X-ray nanodiffraction By journals.iucr.org Published On :: 2024-10-29 The effect of an electric field on local domain structure near a 24° tilt grain boundary in a 200 nm-thick Pb(Zr0.2Ti0.8)O3 bi-crystal ferroelectric film was probed using synchrotron nanodiffraction. The bi-crystal film was grown epitaxially on SrRuO3-coated (001) SrTiO3 24° tilt bi-crystal substrates. From the nanodiffraction data, real-space maps of the ferroelectric domain structure around the grain boundary prior to and during application of a 200 kV cm−1 electric field were reconstructed. In the vicinity of the tilt grain boundary, the distributions of densities of c-type tetragonal domains with the c axis aligned with the film normal were calculated on the basis of diffracted intensity ratios of c- and a-type domains and reference powder diffraction data. Diffracted intensity was averaged along the grain boundary, and it was shown that the density of c-type tetragonal domains dropped to ∼50% of that of the bulk of the film over a range ±150 nm from the grain boundary. This work complements previous results acquired by band excitation piezoresponse force microscopy, suggesting that reduced nonlinear piezoelectric response around grain boundaries may be related to the change in domain structure, as well as to the possibility of increased pinning of domain wall motion. The implications of the results and analysis in terms of understanding the role of grain boundaries in affecting the nonlinear piezoelectric and dielectric responses of ferroelectric materials are discussed. Full Article text
at Integrating machine learning interatomic potentials with hybrid reverse Monte Carlo structure refinements in RMCProfile By journals.iucr.org Published On :: 2024-10-29 Structure refinement with reverse Monte Carlo (RMC) is a powerful tool for interpreting experimental diffraction data. To ensure that the under-constrained RMC algorithm yields reasonable results, the hybrid RMC approach applies interatomic potentials to obtain solutions that are both physically sensible and in agreement with experiment. To expand the range of materials that can be studied with hybrid RMC, we have implemented a new interatomic potential constraint in RMCProfile that grants flexibility to apply potentials supported by the Large-scale Atomic/Molecular Massively Parallel Simulator (LAMMPS) molecular dynamics code. This includes machine learning interatomic potentials, which provide a pathway to applying hybrid RMC to materials without currently available interatomic potentials. To this end, we present a methodology to use RMC to train machine learning interatomic potentials for hybrid RMC applications. Full Article text
at The smearing function for a multi-slit very small angle neutron scattering instrument By journals.iucr.org Published On :: 2024-10-29 Besides traditional pinhole geometry, the multi-slit very small angle neutron scattering instrument (MS-VSANS) at the China Spallation Neutron Source also utilizes a multi-slit collimation system to focus neutrons. Using the special focusing structures, the minimum scattering vector magnitude (q) can reach 0.00028 Å−1. The special structures also lead to a significantly different smearing function. By comparing the results of theoretical calculations with experimental data, we have validated the feasibility of a smearing method based on a mature theory for slit smearing. We use the weight-averaged intensity of neutron wavelength as a representative to evaluate the effect from a broad wavelength distribution, concentrating on the effect from the geometry of the multi-slit structures and the detector. The consistency of the theoretical calculation of the smearing function with experimental VSANS scattering profiles for a series of polystyrene standards of different diameters proves the feasibility of the smearing method. This marks the inaugural use of real experimental data from an instrument employing a multi-slit collimation system. Full Article text
at Sheet-on-sheet fixed target data collection devices for serial crystallography at synchrotron and XFEL sources By journals.iucr.org Published On :: 2024-10-16 Serial crystallography (SX) efficiently distributes over many crystals the radiation dose absorbed during diffraction data acquisition, enabling structure determination of samples at ambient temperature. SX relies on the rapid and reliable replacement of X-ray-exposed crystals with fresh crystals at a rate commensurate with the data acquisition rate. `Solid supports', also known as `fixed targets' or `chips', offer one approach. These are microscopically thin solid panes into or onto which crystals are deposited to be individually interrogated by an X-ray beam. Solid supports are generally patterned using photolithography methods to produce a regular array of features that trap single crystals. A simpler and less expensive alternative is to merely sandwich the microcrystals between two unpatterned X-ray-transparent polymer sheets. Known as sheet-on-sheet (SOS) chips, these offer significantly more versatility. SOS chips place no constraint on the size or size distribution of the microcrystals or their growth conditions. Crystals ranging from true nanocrystals up to microcrystals can be investigated, as can crystals grown in media ranging from low viscosity (aqueous solution) up to high viscosity (such as lipidic cubic phase). Here, we describe our two SOS devices. The first is a compact and lightweight version designed specifically for synchrotron use. It incorporates a standard SPINE-type magnetic base for mounting on a conventional macromolecular crystallography goniometer. The second and larger chip is intended for both X-ray free-electron laser and synchrotron use and is fully compatible with the fast-scanning XY-raster stages developed for data collection with patterned chips. Full Article text
at Laboratory X-ray powder micro-diffraction in the research of painted artworks By journals.iucr.org Published On :: 2024-11-08 Painted artworks represent a significant group of cultural heritage artifacts, which are primarily admired because of their aesthetic quality. Nevertheless, the value of each particular painting depends also on what is known about it. Material investigation of paintings is one of the most reliable sources of information. Materials in painted artworks (i.e. panel, easel and miniature paintings, wall paintings, polychromed sculptures etc.) represent an extensive set of inorganic and organic phases, which are often present in complicated mixtures and exhibit characteristics reflecting their geological genesis (mineral pigments), manufacturing technology (artificial pigments), diverse biological nature (binders or dyes) or secondary changes (degradation or intentional later interventions). The analyses of paintings are often made challenging by the heterogeneous nature and minute size of micro-samples or, in some cases, even by the impossibility of sampling due to the preciousness, fragility or small dimensions of the artwork. This review demonstrates the successful implementation of laboratory X-ray powder micro-diffraction for material investigation of paintings, illustrating its efficiency for mineralogical analysis of (i) earth-based materials indicating the provenance of paintings, (ii) copper-based pigments pointing to their origin, and (iii) products of both salt corrosion and saponification enabling one to reveal the deterioration and probable original appearance of artworks. Full Article text
at On the principle of reciprocity in inelastic electron scattering By journals.iucr.org Published On :: 2024-10-21 In electron microscopy the principle of reciprocity is often used to imply time reversal symmetry. While this is true for elastic scattering, its applicability to inelastic scattering is less well established. From the second law of thermodynamics, the entropy for a thermally isolated system must be constant for any reversible process. Using entropy and statistical fluctuation arguments, it is shown that, while reversibility is possible at the microscopic level, it becomes statistically less likely for higher energy transfers. The implications for reciprocal imaging modes, including energy loss and energy gain measurements, as well as Kainuma's reciprocal wave model are also discussed. Full Article text
at Lattice symmetry relaxation as a cause for anisotropic line broadening and peak shift in powder diffraction By journals.iucr.org Published On :: 2024-10-03 In powder diffraction, lattice symmetry relaxation causes a peak to split into several components which are not resolved if the degree of desymmetrization is small (pseudosymmetry). Here the equations which rule peak splitting are elaborated for the six minimal symmetry transitions, showing that the resulting split peaks are generally broader and asymmetric, and suffer an hkl-dependent displacement with respect to the high-symmetry parent peak. These results will be of help in Rietveld refinement of pseudosymmetric structures where an exact interpretation of peak deformation is required. Full Article text
at An alternative method to the Takagi–Taupin equations for studying dark-field X-ray microscopy of deformed crystals By journals.iucr.org Published On :: 2024-09-26 This study introduces an alternative method to the Takagi–Taupin equations for investigating the dark-field X-ray microscopy (DFXM) of deformed crystals. In scenarios where dynamical diffraction cannot be disregarded, it is essential to assess the potential inaccuracies of data interpretation based on the kinematic diffraction theory. Unlike the Takagi–Taupin equations, this new method utilizes an exact dispersion relation, and a previously developed finite difference scheme with minor modifications is used for the numerical implementation. The numerical implementation has been validated by calculating the diffraction of a diamond crystal with three components, wherein dynamical diffraction is applicable to the first component and kinematic diffraction pertains to the remaining two. The numerical convergence is tested using diffraction intensities. In addition, the DFXM image of a diamond crystal containing a stacking fault is calculated using the new method and compared with the experimental result. The new method is also applied to calculate the DFXM image of a twisted diamond crystal, which clearly shows a result different from those obtained using the Takagi–Taupin equations. Full Article text
at Influence of device configuration and noise on a machine learning predictor for the selection of nanoparticle small-angle X-ray scattering models By journals.iucr.org Published On :: 2024-09-23 Small-angle X-ray scattering (SAXS) is a widely used method for nanoparticle characterization. A common approach to analysing nanoparticles in solution by SAXS involves fitting the curve using a parametric model that relates real-space parameters, such as nanoparticle size and electron density, to intensity values in reciprocal space. Selecting the optimal model is a crucial step in terms of analysis quality and can be time-consuming and complex. Several studies have proposed effective methods, based on machine learning, to automate the model selection step. Deploying these methods in software intended for both researchers and industry raises several issues. The diversity of SAXS instrumentation requires assessment of the robustness of these methods on data from various machine configurations, involving significant variations in the q-space ranges and highly variable signal-to-noise ratios (SNR) from one data set to another. In the case of laboratory instrumentation, data acquisition can be time-consuming and there is no universal criterion for defining an optimal acquisition time. This paper presents an approach that revisits the nanoparticle model selection method proposed by Monge et al. [Acta Cryst. (2024), A80, 202–212], evaluating and enhancing its robustness on data from device configurations not seen during training, by expanding the data set used for training. The influence of SNR on predictor robustness is then assessed, improved, and used to propose a stopping criterion for optimizing the trade-off between exposure time and data quality. Full Article text
at Symmetries and symmetry-generated averages of elastic constants up to the sixth order of nonlinearity for all crystal classes, isotropy and transverse isotropy By journals.iucr.org Published On :: 2024-10-15 Algebraic expressions for averaging linear and nonlinear stiffness tensors from general anisotropy to different effective symmetries (11 Laue classes elastically representing all 32 crystal classes, and two non-crystalline symmetries: isotropic and cylindrical) have been derived by automatic symbolic computations of the arithmetic mean over the set of rotational transforms determining a given symmetry. This approach generalizes the Voigt average to nonlinear constants and desired approximate symmetries other than isotropic, which can be useful for a description of textured polycrystals and rocks preserving some symmetry aspects. Low-symmetry averages have been used to derive averages of higher symmetry to speed up computations. Relationships between the elastic constants of each symmetry have been deduced from their corresponding averages by resolving the rank-deficient system of linear equations. Isotropy has also been considered in terms of generalized Lamé constants. The results are published in the form of appendices in the supporting information for this article and have been deposited in the Mendeley database. Full Article text
at Crystal structure, Hirshfeld surface analysis, DFT and molecular docking studies of ethyl 5-amino-2-bromoisonicotinate By journals.iucr.org Published On :: 2024-11-08 In the title compound, C8H9BrN2O2, the C—O—C—C torsion angle between isonicotine and the ethyl group is 180.0 (2)°. Intramolecular N—H...O and C—H...O interactions consolidate the molecular structure. In the crystal, N—H...N interaction form S(5) zigzag chains along [010]. The most significant contributions to the Hirshfeld surface arise from H...H (33.2%), Br...H/H...Br (20.9%), O...H/H...O (11.2%), C...H/H...C (11.1%) and N...H/H...N (10%) contacts. The topology of the three-dimensional energy frameworks was generated using the B3LYP/6–31 G(d,p) model to calculate the total interaction energy. The net interaction energies for the title compound are Eele = 59.2 kJ mol−1, Epol = 15.5 kJ mol−1, Edis = 140.3 kJ mol−1 and Erep = 107.2 kJ mol−1 with a total interaction energy Etot of 128.8 kJ mol−1. The molecular structure was optimized by density functional theory (DFT) at the B3LYP/6–311+G(d,p) level and the theoretical and experimentally obtained parameters were compared. The frontier molecular orbitals HOMO and LUMO were generated, giving an energy gap ΔE of 4.0931 eV. The MEP was generated to identify active sites in the molecule and molecular docking studies carried out with the title compound (ligand) and the covid-19 main protease PDB ID: 6LU7, revealing a moderate binding affinity of −5.4 kcal mol−1. Full Article text
at Crystal structure and Hirshfeld-surface analysis of an etoxazole metabolite designated R13 By journals.iucr.org Published On :: 2024-11-08 The etoxazole metabolite R13, systematic name 4-(4-tert-butyl-2-ethoxyphenyl)-2-(2,6-difluorophenyl)oxazole (C21H21F2NO2), results from the oxidation of etoxazole, a chitin synthesis inhibitor belonging to the oxazoline class, widely used as an insecticide/acaricide since 1998. The structure of R13 features a central oxazole ring with attached 2,6-difluorophenyl and 4-t-butyl-2-ethoxyphenyl moieties. The overall conformation gives dihedral angles between these rings and the oxazole of 24.91 (5)° (with difluorophenyl) and 15.30 (6)° (with t-butyl-ethoxyphenyl), indicating an overall deviation from planarity. Additionally, torsion angles of the ethoxy and t-butyl groups define the orientation of these substituents relative to their benzene ring. In the crystal packing, no significant hydrogen bonds are present, but a Hirshfeld surface analysis highlights weak intermolecular contacts leading to π–π-stacked dimers linked by weak C—H...N contacts. The packing analysis confirms that most intermolecular interactions involve hydrogen atoms. Full Article text
at Crystal structure of a solvated dinuclear CuII complex derived from 3,3,3',3'-tetraethyl-1,1'-(furan-2,5-dicarbonyl)bis(thiourea) By journals.iucr.org Published On :: 2024-11-08 Reaction between equimolar amounts of 3,3,3',3'-tetraethyl-1,1'-(furan-2,5-dicarbonyl)bis(thiourea) (H2L) and CuCl2·2H2O in methanol in the presence of the supporting base Et3N gave rise to a neutral dinuclear complex bis[μ-3,3,3',3'-tetraethyl-1,1'-(furan-2,5-dicarbonyl)bis(thioureato)]dicopper(II) dichloromethane disolvate, [Cu2(C16H22N4O3S2)2]·2CH2Cl2 or [Cu2(L)2]·2CH2Cl2. The aroylbis(thioureas) are doubly deprotonated and the resulting anions {L2–} bond to metal ions through (S,O)-chelating moieties. The copper atoms adopt a virtually cis-square-planar environment. In the crystal, adjacent [Cu2(L)2]·2CH2Cl2 units are linked into polymeric chains along the a-axis direction by intermolecular coordinative Cu...S interactions. The co-crystallized solvent molecules play a vital role in the crystal packing. In particular, weak C—Hfuran...Cl and C—Hethyl...Cl contacts consolidate the three-dimensional supramolecular architecture. Full Article text
at Crystal structures and circular dichroism of {2,2'-[(1S,2S)-1,2-diphenylethane-1,2-diylbis(nitrilophenylmethanylylidene)]diphenolato}nickel(II) and its ethanol solvate By journals.iucr.org Published On :: 2024-11-08 The title compound, [Ni(C40H30N2O2)] (1), with an optically active Schiff base ligand derived from 2-hydroxybenzophenone and (1S,2S)-1,2-diphenylethylenediamine, was crystallized as the solvent-free and ethanol solvate forms (1 and 1·2C2H5OH). In both structures, the two phenyl groups on the stereogenic centers of the O,N,N,O-tetradentate ligand are axially oriented, and the conformation of the central diamine chelate ring is λ. The circular dichroism (CD) spectra of 1 and the analogous nickel(II) complex [Ni(C30H26N2O2)] (2) in solution show partially similar patterns in the 350–450 nm range, but are mirror images in the longer wavelength region (450–650 nm). In the latter region, the sign of CD for these complexes is sensitive to the substituents on the C=N carbon atoms (phenyl for 1 and methyl for 2) rather than the diamine chelate ring conformation. Full Article text
at In situ/operando plug-flow fixed-bed cell for synchrotron PXRD and XAFS investigations at high temperature, pressure, controlled gas atmosphere and ultra-fast heating By journals.iucr.org Published On :: 2024-01-01 A plug-flow fixed-bed cell for synchrotron powder X-ray diffraction (PXRD) and X-ray absorption fine structure (XAFS) idoneous for the study of heterogeneous catalysts at high temperature, pressure and under gas flow is designed, constructed and demonstrated. The operating conditions up to 1000°C and 50 bar are ensured by a set of mass flow controllers, pressure regulators and two infra-red lamps that constitute a robust and ultra-fast heating and cooling method. The performance of the system and cell for carbon dioxide hydrogenation reactions under specified temperatures, gas flows and pressures is demonstrated both for PXRD and XAFS at the P02.1 (PXRD) and the P64 (XAFS) beamlines of the Deutsches Elektronen-Synchrotron (DESY). Full Article text
at Treatment of multiple-beam X-ray diffraction in energy-dependent measurements By journals.iucr.org Published On :: 2024-01-01 During X-ray diffraction experiments on single crystals, the diffracted beam intensities may be affected by multiple-beam X-ray diffraction (MBD). This effect is particularly frequent at higher X-ray energies and for larger unit cells. The appearance of this so-called Renninger effect often impairs the interpretation of diffracted intensities. This applies in particular to energy spectra analysed in resonant experiments, since during scans of the incident photon energy these conditions are necessarily met for specific X-ray energies. This effect can be addressed by carefully avoiding multiple-beam reflection conditions at a given X-ray energy and a given position in reciprocal space. However, areas which are (nearly) free of MBD are not always available. This article presents a universal concept of data acquisition and post-processing for resonant X-ray diffraction experiments. Our concept facilitates the reliable determination of kinematic (MBD-free) resonant diffraction intensities even at relatively high energies which, in turn, enables the study of higher absorption edges. This way, the applicability of resonant diffraction, e.g. to reveal the local atomic and electronic structure or chemical environment, is extended for a vast majority of crystalline materials. The potential of this approach compared with conventional data reduction is demonstrated by the measurements of the Ta L3 edge of well studied lithium tantalate LiTaO3. Full Article text
at Similarity score for screening phase-retrieved maps in X-ray diffraction imaging – characterization in reciprocal space By journals.iucr.org Published On :: 2024-01-01 X-ray diffraction imaging (XDI) is utilized for visualizing the structures of non-crystalline particles in material sciences and biology. In the structural analysis, phase-retrieval (PR) algorithms are applied to the diffraction amplitude data alone to reconstruct the electron density map of a specimen particle projected along the direction of the incident X-rays. However, PR calculations may not lead to good convergence because of a lack of diffraction patterns in small-angle regions and Poisson noise in X-ray detection. Therefore, the PR calculation is still a bottleneck for the efficient application of XDI in the structural analyses of non-crystalline particles. For screening maps from hundreds of trial PR calculations, we have been using a score and measuring the similarity between a pair of retrieved maps. Empirically, probable maps approximating the particle structures gave a score smaller than a threshold value, but the reasons for the effectiveness of the score are still unclear. In this study, the score is characterized in terms of the phase differences between the structure factors of the retrieved maps, the usefulness of the score in screening the maps retrieved from experimental diffraction patterns is demonstrated, and the effective resolution of similarity-score-selected maps is discussed. Full Article text
at Protocol using similarity score and improved shrink-wrap algorithm for better convergence of phase-retrieval calculation in X-ray diffraction imaging By journals.iucr.org Published On :: 2024-01-01 In X-ray diffraction imaging (XDI), electron density maps of a targeted particle are reconstructed computationally from the diffraction pattern alone using phase-retrieval (PR) algorithms. However, the PR calculations sometimes fail to yield realistic electron density maps that approximate the structure of the particle. This occurs due to the absence of structure amplitudes at and near the zero-scattering angle and the presence of Poisson noise in weak diffraction patterns. Consequently, the PR calculation becomes a bottleneck for XDI structure analyses. Here, a protocol to efficiently yield realistic maps is proposed. The protocol is based on the empirical observation that realistic maps tend to yield low similarity scores, as suggested in our prior study [Sekiguchi et al. (2017), J. Synchrotron Rad. 24, 1024–1038]. Among independently and concurrently executed PR calculations, the protocol modifies all maps using the electron-density maps exhibiting low similarity scores. This approach, along with a new protocol for estimating particle shape, improved the probability of obtaining realistic maps for diffraction patterns from various aggregates of colloidal gold particles, as compared with PR calculations performed without the protocol. Consequently, the protocol has the potential to reduce computational costs in PR calculations and enable efficient XDI structure analysis of non-crystalline particles using synchrotron X-rays and X-ray free-electron laser pulses. Full Article text
at Deep learning to overcome Zernike phase-contrast nanoCT artifacts for automated micro-nano porosity segmentation in bone By journals.iucr.org Published On :: 2024-01-01 Bone material contains a hierarchical network of micro- and nano-cavities and channels, known as the lacuna-canalicular network (LCN), that is thought to play an important role in mechanobiology and turnover. The LCN comprises micrometer-sized lacunae, voids that house osteocytes, and submicrometer-sized canaliculi that connect bone cells. Characterization of this network in three dimensions is crucial for many bone studies. To quantify X-ray Zernike phase-contrast nanotomography data, deep learning is used to isolate and assess porosity in artifact-laden tomographies of zebrafish bones. A technical solution is proposed to overcome the halo and shade-off domains in order to reliably obtain the distribution and morphology of the LCN in the tomographic data. Convolutional neural network (CNN) models are utilized with increasing numbers of images, repeatedly validated by `error loss' and `accuracy' metrics. U-Net and Sensor3D CNN models were trained on data obtained from two different synchrotron Zernike phase-contrast transmission X-ray microscopes, the ANATOMIX beamline at SOLEIL (Paris, France) and the P05 beamline at PETRA III (Hamburg, Germany). The Sensor3D CNN model with a smaller batch size of 32 and a training data size of 70 images showed the best performance (accuracy 0.983 and error loss 0.032). The analysis procedures, validated by comparison with human-identified ground-truth images, correctly identified the voids within the bone matrix. This proposed approach may have further application to classify structures in volumetric images that contain non-linear artifacts that degrade image quality and hinder feature identification. Full Article text
at Heitt Mjölnir: a heated miniature triaxial apparatus for 4D synchrotron microtomography By journals.iucr.org Published On :: 2024-01-01 Third- and fourth-generation synchrotron light sources with high fluxes and beam energies enable the use of innovative X-ray translucent experimental apparatus. These experimental devices access geologically relevant conditions whilst enabling in situ characterization using the spatial and temporal resolutions accessible at imaging beamlines. Here, Heitt Mjölnir is introduced, a heated miniature triaxial rig based on the design of Mjölnir, but covering a wider temperature range and larger sample volume at similar pressure capacities. This device is designed to investigate coupled thermal, chemical, hydraulic and mechanical processes from grain to centimetre scales using cylindrical samples of 10 mm × 20 mm (diameter × length). Heitt Mjölnir can simultaneously reach confining (hydraulic) pressures of 30 MPa and 500 MPa of axial stress with independently controlled sample pore fluid pressure < 30 MPa. This internally heated apparatus operates to temperatures up to 573 K with a minimal vertical thermal gradient in the sample of <0.3 K mm−1. This new apparatus has been deployed in operando studies at the TOMCAT (Swiss Light Source), I12 JEEP (Diamond Light Source) and PSICHÉ (Synchrotron SOLEIL) beamlines for 4D X-ray microtomography with scan intervals of a few minutes. Heitt Mjölnir is portable and modular, allowing a wide range of 4D characterizations of low-grade metamorphism and deformational processes. It enables spatially and temporally resolved fluid–rock interaction studies at conditions of crustal reservoirs and is suitable for characterization of material properties in geothermal, carbonation or subsurface gas storage applications. Technical drawings and an operation guide are included in this publication. Full Article text
at In situ characterization of stresses, deformation and fracture of thin films using transmission X-ray nanodiffraction microscopy By journals.iucr.org Published On :: 2024-01-01 The use of hard X-ray transmission nano- and microdiffraction to perform in situ stress and strain measurements during deformation has recently been demonstrated and used to investigate many thin film systems. Here a newly commissioned sample environment based on a commercially available nanoindenter is presented, which is available at the NanoMAX beamline at the MAX IV synchrotron. Using X-ray nanoprobes of around 60–70 nm at 14–16 keV and a scanning step size of 100 nm, we map the strains, stresses, plastic deformation and fracture during nanoindentation of industrial coatings with thicknesses in the range of several micrometres, relatively strong texture and large grains. The successful measurements of such challenging samples illustrate broad applicability. The sample environment is openly accessible for NanoMAX beamline users through the MAX IV sample environment pool, and its capability can be further extended for specific purposes through additional available modules. Full Article text
at Angle-resolved X-ray emission spectroscopy facility realized by an innovative spectrometer rotation mechanism at SPring-8 BL07LSU By journals.iucr.org Published On :: 2024-02-01 The X-ray emission spectrometer at SPring-8 BL07LSU has recently been upgraded with advanced modifications that enable the rotation of the spectrometer with respect to the scattering angle. This major upgrade allows the scattering angle to be flexibly changed within the range of 45–135°, which considerably simplifies the measurement of angle-resolved X-ray emission spectroscopy. To accomplish the rotation system, a sophisticated sample chamber and a highly precise spectrometer rotation mechanism have been developed. The sample chamber has a specially designed combination of three rotary stages that can smoothly move the connection flange along the wide scattering angle without breaking the vacuum. In addition, the spectrometer is rotated by sliding on a flat metal surface, ensuring exceptionally high accuracy in rotation and eliminating the need for any further adjustments during rotation. A control system that integrates the sample chamber and rotation mechanism to automate the measurement of angle-resolved X-ray emission spectroscopy has also been developed. This automation substantially streamlines the process of measuring angle-resolved spectra, making it far easier than ever before. Furthermore, the upgraded X-ray emission spectrometer can now also be utilized in diffraction experiments, providing even greater versatility to our research capabilities. Full Article text
at Combination of XEOL, TR-XEOL and HB-T interferometer at the TPS 23A X-ray nanoprobe for exploring quantum materials By journals.iucr.org Published On :: 2024-01-19 In this study, a combination of X-ray excited optical luminescence (XEOL), time-resolved XEOL (TR-XEOL) and the Hanbury-Brown and Twiss (HB-T) interferometer at the Taiwan Photon Source (TPS) 23A X-ray nanoprobe beamline for exploring quantum materials is demonstrated. On the basis of the excellent spatial resolution rendered using a nano-focused beam, emission distributions of artificial micro-diamonds can be obtained by XEOL maps, and featured emission peaks of a selected local area can be obtained by XEOL spectra. The hybrid bunch mode of the TPS not only provides a sufficiently high peak power density for experiments at each beamline but also permits high-quality temporal domain (∼200 ns) measurements for investigating luminescence dynamics. From TR-XEOL measurements, the decay lifetime of micro-diamonds is determined to be approximately 16 ns. Furthermore, the XEOL spectra of artificial micro-diamonds can be investigated by the HB-T interferometer to identify properties of single-photon sources. The unprecedented strategy of combining XEOL, TR-XEOL and the HB-T interferometer at the X-ray nanoprobe beamline will open new avenues with significant characterization abilities for unraveling the emission mechanisms of single-photon sources for quantum materials. Full Article text
at Correlation of refractive index based and THz streaking arrival time tools for a hard X-ray free-electron laser By journals.iucr.org Published On :: 2024-01-22 To fully exploit ultra-short X-ray pulse durations routinely available at X-ray free-electron lasers to follow out-of-equilibrium dynamics, inherent arrival time fluctuations of the X-ray pulse with an external perturbing laser pulse need to be measured. In this work, two methods of arrival time measurement were compared to measure the arrival time jitter of hard X-ray pulses. The methods were photoelectron streaking by a THz field and a transient refractive index change of a semiconductor. The methods were validated by shot-to-shot correction of a pump–probe transient reflectivity measurement. An ultimate shot-to-shot full width at half-maximum error between the devices of 19.2 ± 0.1 fs was measured. Full Article text
at Finback: a web-based data collection system at SSRF biological macromolecular crystallography beamlines By journals.iucr.org Published On :: 2024-01-19 An integrated computer software system for macromolecular crystallography (MX) data collection at the BL02U1 and BL10U2 beamlines of the Shanghai Synchrotron Radiation Facility is described. The system, Finback, implements a set of features designed for the automated MX beamlines, and is marked with a user-friendly web-based graphical user interface (GUI) for interactive data collection. The Finback client GUI can run on modern browsers and has been developed using several modern web technologies including WebSocket, WebGL, WebWorker and WebAssembly. Finback supports multiple concurrent sessions, so on-site and remote users can access the beamline simultaneously. Finback also cooperates with the deployed experimental data and information management system, the relevant experimental parameters and results are automatically deposited to a database. Full Article text
at A thermal deformation optimization method for cryogenically cooled silicon crystal monochromators under high heat load By journals.iucr.org Published On :: 2024-01-22 A method to optimize the thermal deformation of an indirectly cryo-cooled silicon crystal monochromator exposed to intense X-rays at a low-emittance diffraction-limited synchrotron radiation source is presented. The thermal-induced slope error of the monochromator crystal has been studied as a function of heat transfer efficiency, crystal temperature distribution and beam footprint size. A partial cooling method is proposed, which flattens the crystal surface profile within the beam footprint by modifying the cooling contact area to optimize the crystal peak temperature. The optimal temperature varies with different photon energies, which is investigated, and a proper cooling strategy is obtained to fulfil the thermal distortion requirements over the entire photon energy range. At an absorbed power up to 300 W with a maximum power density of 44.8 W mm−2 normal incidence beam from an in-vacuum undulator, the crystal thermal distortion does not exceed 0.3 µrad at 8.33 keV. This method will provide references for the monochromator design on diffraction-limited synchrotron radiation or free-electron laser light sources. Full Article text
at A new modular framework for high-level application development at HEPS By journals.iucr.org Published On :: 2024-02-01 As a representative of the fourth-generation light sources, the High Energy Photon Source (HEPS) in Beijing, China, utilizes a multi-bend achromat lattice to obtain an approximately 100 times emittance reduction compared with third-generation light sources. New technologies bring new challenges to operate the storage ring. In order to meet the beam commissioning requirements of HEPS, a new framework for the development of high-level applications (HLAs) has been created. The key part of the new framework is a dual-layer physical module to facilitate the seamless fusion of physical simulation models with the real machine, allowing for fast switching between different simulation models to accommodate the various simulation scenarios. As a framework designed for development of physical applications, all variables are based on physical quantities. This allows physicists to analytically assess measurement parameters and optimize machine parameters in a more intuitive manner. To enhance both extensibility and adaptability, a modular design strategy is utilized, partitioning the entire framework into discrete modules in alignment with the requirements of HLA development. This strategy not only facilitates the independent development of each module but also minimizes inter-module coupling, thereby simplifying the maintenance and expansion of the entire framework. To simplify the development complexity, the design of the new framework is implemented using Python and is called Python-based Accelerator Physics Application Set (Pyapas). Taking advantage of Python's flexibility and robust library support, we are able to develop and iterate quickly, while also allowing for seamless integration with other scientific computing applications. HLAs for both the HEPS linac and booster have been successfully developed. During the beam commissioning process at the linac, Pyapas's ease of use and reliability have significantly reduced the time required for the beam commissioning operators. As a development framework for HLA designed for the new-generation light sources, Pyapas has the versatility to be employed with HEPS, as well as with other comparable light sources, due to its adaptability. Full Article text
at Submillisecond in situ X-ray diffraction measurement system with changing temperature and pressure using diamond anvil cells at BL10XU/SPring-8 By journals.iucr.org Published On :: 2024-02-19 Recently, there has been a high demand for elucidating kinetics and visualizing reaction processes under extreme dynamic conditions, such as chemical reactions under meteorite impact conditions, structural changes under nonequilibrium conditions, and in situ observations of dynamic changes. To accelerate material science studies and Earth science fields under dynamic conditions, a submillisecond in situ X-ray diffraction measurement system has been developed using a diamond anvil cell to observe reaction processes under rapidly changing pressure and temperature conditions replicating extreme dynamic conditions. The development and measurements were performed at the high-pressure beamline BL10XU/SPring-8 by synchronizing a high-speed hybrid pixel array detector, laser heating and temperature measurement system, and gas-pressure control system that enables remote and rapid pressure changes using the diamond anvil cell. The synchronized system enabled momentary heating and rapid cooling experiments up to 5000 K via laser heating as well as the visualization of structural changes in high-pressure samples under extreme dynamic conditions during high-speed pressure changes. Full Article text
at xrdPlanner: exploring area detector geometries for powder diffraction and total scattering experiments By journals.iucr.org Published On :: 2024-02-02 xrdPlanner is a software package designed to aid in the planning and preparation of powder X-ray diffraction and total scattering beam times at synchrotron facilities. Many modern beamlines provide a flexible experimental setup and may have several different detectors available. In combination with a range of available X-ray energies, it often makes it difficult for the user to explore the available parameter space relevant for a given experiment prior to the scheduled beam time. xrdPlanner was developed to provide a fast and straightforward tool that allows users to visualize the accessible part of reciprocal space of their experiment at a given combination of photon energy and detector geometry. To plan and communicate the necessary geometry not only saves time but also helps the beamline staff to prepare and accommodate for an experiment. The program is tailored toward powder X-ray diffraction and total scattering experiments but may also be useful for other experiments that rely on an area detector and for which detector placement and achievable momentum-transfer range are important experimental parameters. Full Article text
at DOMAS: a data management software framework for advanced light sources By journals.iucr.org Published On :: 2024-02-01 In recent years, China's advanced light sources have entered a period of rapid construction and development. As modern X-ray detectors and data acquisition technologies advance, these facilities are expected to generate massive volumes of data annually, presenting significant challenges in data management and utilization. These challenges encompass data storage, metadata handling, data transfer and user data access. In response, the Data Organization Management Access Software (DOMAS) has been designed as a framework to address these issues. DOMAS encapsulates four fundamental modules of data management software, including metadata catalogue, metadata acquisition, data transfer and data service. For light source facilities, building a data management system only requires parameter configuration and minimal code development within DOMAS. This paper firstly discusses the development of advanced light sources in China and the associated demands and challenges in data management, prompting a reconsideration of data management software framework design. It then outlines the architecture of the framework, detailing its components and functions. Lastly, it highlights the application progress and effectiveness of DOMAS when deployed for the High Energy Photon Source (HEPS) and Beijing Synchrotron Radiation Facility (BSRF). Full Article text
at Extracting the electronic structure signal from X-ray and electron scattering in the gas phase By journals.iucr.org Published On :: 2024-02-22 X-ray and electron scattering from free gas-phase molecules is examined using the independent atom model (IAM) and ab initio electronic structure calculations. The IAM describes the effect of the molecular geometry on the scattering, but does not account for the redistribution of valence electrons due to, for instance, chemical bonding. By examining the total, i.e. energy-integrated, scattering from three molecules, fluoroform (CHF3), 1,3-cyclohexadiene (C6H8) and naphthalene (C10H8), the effect of electron redistribution is found to predominantly reside at small-to-medium values of the momentum transfer (q ≤ 8 Å−1) in the scattering signal, with a maximum percent difference contribution at 2 ≤ q ≤ 3 Å−1. A procedure to determine the molecular geometry from the large-q scattering is demonstrated, making it possible to more clearly identify the deviation of the scattering from the IAM approximation at small and intermediate q and to provide a measure of the effect of valence electronic structure on the scattering signal. Full Article text
at Image registration for in situ X-ray nano-imaging of a composite battery cathode with deformation By journals.iucr.org Published On :: 2024-02-01 The structural and chemical evolution of battery electrodes at the nanoscale plays an important role in affecting the cell performance. Nano-resolution X-ray microscopy has been demonstrated as a powerful technique for characterizing the evolution of battery electrodes under operating conditions with sensitivity to their morphology, compositional distribution and redox heterogeneity. In real-world batteries, the electrode could deform upon battery operation, causing challenges for the image registration which is necessary for several experimental modalities, e.g. XANES imaging. To address this challenge, this work develops a deep-learning-based method for automatic particle identification and tracking. This approach was not only able to facilitate image registration with good robustness but also allowed quantification of the degree of sample deformation. The effectiveness of the method was first demonstrated using synthetic datasets with known ground truth. The method was then applied to an experimental dataset collected on an operating lithium battery cell, revealing a high degree of intra- and interparticle chemical complexity in operating batteries. Full Article text
at Enhancing electrospray ionization efficiency for particle transmission through an aerodynamic lens stack By journals.iucr.org Published On :: 2024-02-02 This work investigates the performance of the electrospray aerosol generator at the European X-ray Free Electron Laser (EuXFEL). This generator is, together with an aerodynamic lens stack that transports the particles into the X-ray interaction vacuum chamber, the method of choice to deliver particles for single-particle coherent diffractive imaging (SPI) experiments at the EuXFEL. For these experiments to be successful, it is necessary to achieve high transmission of particles from solution into the vacuum interaction region. Particle transmission is highly dependent on efficient neutralization of the charged aerosol generated by the electrospray mechanism as well as the geometry in the vicinity of the Taylor cone. We report absolute particle transmission values for different neutralizers and geometries while keeping the conditions suitable for SPI experiments. Our findings reveal that a vacuum ultraviolet ionizer demonstrates a transmission efficiency approximately seven times greater than the soft X-ray ionizer used previously. Combined with an optimized orifice size on the counter electrode, we achieve >40% particle transmission from solution into the X-ray interaction region. These findings offer valuable insights for optimizing electrospray aerosol generator configurations and data rates for SPI experiments. Full Article text
at Ultrashort large-bandwidth X-ray free-electron laser generation with a dielectric-lined waveguide By journals.iucr.org Published On :: 2024-02-09 Large-bandwidth pulses produced by cutting-edge X-ray free-electron lasers (FELs) are of great importance in research fields like material science and biology. In this paper, a new method to generate high-power ultrashort FEL pulses with tunable spectral bandwidth with spectral coherence using a dielectric-lined waveguide without interfering operation of linacs is proposed. By exploiting the passive and dephasingless wakefield at terahertz frequency excited by the beam, stable energy modulation can be achieved in the electron beam and large-bandwidth high-intensity soft X-ray radiation can be generated. Three-dimensional start-to-end simulations have been carried out and the results show that coherent radiation pulses with duration of a few femtoseconds and bandwidths ranging from 1.01% to 2.16% can be achieved by changing the undulator taper profile. Full Article text
at Grazing-incidence synchrotron radiation diffraction studies on irradiated Ce-doped and pristine Y-stabilized ZrO2 at the Rossendorf beamline By journals.iucr.org Published On :: 2024-02-16 In this work, Ce-doped yttria-stabilized zirconia (YSZ) and pure YSZ phases were subjected to irradiation with 14 MeV Au ions. Irradiation studies were performed to simulate long-term structural and microstructural damage due to self-irradiation in YSZ phases hosting alpha-active radioactive species. It was found that both the Ce-doped YSZ and the YSZ phases had a reasonable tolerance to irradiation at high ion fluences and the bulk crystallinity was well preserved. Nevertheless, local microstrain increased in all compounds under study after irradiation, with the Ce-doped phases being less affected than pure YSZ. Doping with cerium ions increased the microstructural stability of YSZ phases through a possible reduction in the mobility of oxygen atoms, which limits the formation of structural defects. Doping of YSZ with tetravalent actinide elements is expected to have a similar effect. Thus, YSZ phases are promising for the safe long-term storage of radioactive elements. Using synchrotron radiation diffraction, measurements of the thin irradiated layers of the Ce-YSZ and YSZ samples were performed in grazing incidence (GI) mode. A corresponding module for measurements in GI mode was developed at the Rossendorf Beamline and relevant technical details for sample alignment and data collection are also presented. Full Article text
at Investigation of structural and reflective characteristics of short-period Mo/B4C multilayer X-ray mirrors By journals.iucr.org Published On :: 2024-02-09 The results of a study of the structural and reflective characteristics of short-period multilayer X-ray mirrors based on Mo/B4C at wavelengths 1.54 Å, 9.89 Å and 17.59 Å are presented. The period of the samples varied in the range 8–35 Å. The average widths of the interfaces were ∼3.5 and 2.2 Å at one and the other boundaries, with a tendency for weak growth with any decrease in the period. The interlayer roughness was ∼1 Å. The research results indicate promising prospects for the use of multilayer Mo/B4C mirrors for synchrotron applications. Full Article text